Abstract
One of the most relevant physiological parameters in dogs is respiratory rate (RR). The aim of this paper is to present a novel wearable system that allows to accurately estimate RR in dogs, and to compare it to a gold standard in static conditions. Data from 12 dogs were acquired while the animals were anesthetized and attached to a vital signs monitor. The experimental setup consisted of three Inertial Measurement Units (IMUs) applied on the dog, and a video camera filming the RR value shown on the monitor. The range of RR values analyzed in the study is 0 to 29 breaths per minute, read by the vital signs monitor. The mean RMSE for the acquisitions is 1.68 breaths per minute. The values of the filtering parameters that allow to obtain the best performance depend on the specific acquisition. This result shows that adaptive filtering can be used for the application. Future developments include tests on a larger dataset, and trials on dogs in unconstrained environments and during movement. RR is a vital parameter that is often counted manually both in human and veterinary medicine. This paper presents a wearable system to monitor RR in dogs with the perspective of being applied in various settings, from the resting in-hospital to the outdoor exercising patient.
Funding Information
  • National Plan for NRRP Complementary Investments (PNC0000003)

This publication has 34 references indexed in Scilit: