The presence of contrast agent increases organ radiation dose in contrast-enhanced CT
Authors:
Open Access
- 30 March 2021
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 31 (10) , 7540-7549
Abstract
Objectives: Routine dosimetry calculations do not account for the presence of iodine in organs and tissues during CT acquisition. This study aims to investigate the impact of contrast agent (CA) on radiation dose.Methods: First, relation between absorbed radiation dose and iodine concentrations was investigated using a cylindrical water phantom with iodine-saline dilution insertions. Subsequently, a retrospective study on abdominal dual-energy CT (DECT) patient data was performed to assess the increase of the local absorbed radiation dose compared to a non-contrast scan. Absorbed doses were estimated with Monte Carlo simulations using the individual CT voxel data of phantom and patients. Further, organ segmentations were performed to obtain the dose in liver, liver parenchyma, left kidney, right kidney, aorta, and spleen.Results: In the phantom study, a linear relation was observed between the radiation dose normalized by computed tomography dose index (CTDI) and CA concentrations Iconc(mg/ml) for three tube voltages; $$ \frac{D_{80 kVp}}{CTDI_{vol}} $$ = 0.14 × Iconc+ 1.02, $$ \frac{D_{120 kVp}}{CTDI_{vol}} $$ = 0.16 × Iconc+ 1.21, $$ \frac{D_{140 kVp}}{CTDI_{vol}} $$ = 0.16 × Iconc+ 1.24, and for DECT acquisition; $$ \frac{D_{DECT}}{CTDI_{vol}} $$ = 0.15 × Iconc+ 1.09. Similarly, a linear relation was observed between the dose increase and the organ iodine contents (R2= 0.86 andpvalue< 0.01) in the patient study. The relative doses increased in the liver (21 ± 5%), liver parenchyma (20 ± 5%), right kidney (37 ± 7%), left kidney (39 ± 7%), aorta (34 ± 6%) and spleen (26 ± 4%). In addition, the local dose distributions changed based on patient’s anatomy and physiology.Conclusions: Compared to a non-contrast scan, the organ doses increase by 30% in contrast-enhanced abdominal CT. This study suggests considering CA in dosimetry calculations, epidemiological studies, and organ dose estimations while developing new CT protocols.Key Points: • The presence of contrast media increases radiation absorption in CT, and this increase is related to the iodine content in the organs.• The increased radiation absorption due to contrast media can lead to an average 30% increase in absorbed organ dose.•Iodine should be considered in CT radiation safety studies.
Keywords
Funding Information
- Fonds Wetenschappelijk Onderzoek (1S52720N)
This publication has 31 references indexed in Scilit:
- Iodine Dose of Administered Contrast Media Affects the Level of Radiation-Induced DNA Damage During Cardiac CT ScansAmerican Journal of Roentgenology, 2019
- Post-contrast acute kidney injury. Part 2: risk stratification, role of hydration and other prophylactic measures, patients taking metformin and chronic dialysis patientsEuropean Radiology, 2018
- The impact of iodinated contrast media on intravascular and extravascular absorbed doses in X-ray imaging: A microdosimetric analysisPhysica Medica, 2018
- Enhanced radiation damage caused by iodinated contrast agents during CT examinationEuropean Journal of Radiology, 2017
- The Effect of Contrast Material on Radiation Dose at CT: Part I. Incorporation of Contrast Material Dynamics in Anthropomorphic PhantomsRadiology, 2017
- Assessment of DNA double‐strand breaks induced by intravascular iodinated contrast media following in vitro irradiation and in vivo, during paediatric cardiac catheterizationContrast Media & Molecular Imaging, 2015
- Intravenous Iodinated Contrast Agents Amplify DNA Radiation Damage at CTRadiology, 2015
- Influence of different iodinated contrast media on the induction of DNA double‐strand breaks after in vitro X‐ray irradiationContrast Media & Molecular Imaging, 2014
- Body CT: Technical Advances for Improving SafetyAmerican Journal of Roentgenology, 2011
- Contrast Medium–enhanced Radiation Damage Caused by CT ExaminationsRadiology, 2009