Low sensitivity of implant sonication when screening for infection in revision surgery
Open Access
- 13 March 2017
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 88 (3) , 294-299
Abstract
Background and purpose - Prosthetic-joint infection (PJI) is the most serious complication of arthroplasty, and accurate identification of a potentially responsible microorganism is essential for successful antibiotic treatment. We therefore determined the diagnostic accuracy of sonication and compared it with tissue culture as a screening tool in detecting prosthetic joint infection in revision arthroplasty. Patients and methods - 252 consecutive revision arthroplasty cases were enrolled. These cases were determined as being suspected or unsuspected of having infection according to standard criteria. Perioperatively, 6 periprosthetic interface tissue biopsies were obtained from each patient and the implants removed were sonicated. The sensitivity and specificity of periprosthetic tissue culture and sonication fluid cultures were determined. Results - Preoperatively, 75 revision cases were classified as having PJI (33 early and 42 late) and 177 were unsuspected of having infection. Compared with tissue culture, the sensitivity of the sonication fluid analysis was low: 0.47 (95% CI: 0.35-0.59) for sonication as compared to 0.68 (95% CI: 0.56-0.78) for tissue culture. The specificity of the sonication fluid analysis was higher than that for tissue culture: 0.99 (95% CI: 0.96-1.0) as compared to 0.80 (95% CI: 0.74-0.86). Interpretation - Sonication is a highly specific test for diagnosis of PJI. However, due to the low sensitivity, a negative sonication result does not rule out the presence of PJI. Thus, sonication is not of value for screening of microorganisms during revision surgery.Keywords
This publication has 24 references indexed in Scilit:
- Removed Antibiotic-Impregnated Cement Spacers in Two-Stage Revision Joint Arthroplasty Do Not Show Biofilm Formation In VivoThe Journal of Arthroplasty, 2012
- Infection Associated with Prosthetic JointsThe New England journal of medicine, 2009
- Microbiologic Diagnosis of Prosthetic Shoulder Infection by Use of Implant SonicationJournal of Clinical Microbiology, 2009
- Diagnosis of periprosthetic infection following total hip arthroplasty – evaluation of the diagnostic values of pre- and intraoperative parameters and the associated strategy to preoperatively select patients with a high probability of joint infectionJournal of Orthopaedic Surgery and Research, 2008
- The value of synovial biopsy, joint aspiration and C-reactive protein in the diagnosis of late peri-prosthetic infection of total knee replacementsThe Journal of Bone and Joint Surgery. British volume, 2008
- Culture-Negative Prosthetic Joint InfectionClinical Infectious Diseases, 2007
- Sonication of Removed Hip and Knee Prostheses for Diagnosis of InfectionThe New England journal of medicine, 2007
- Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030Journal of Bone and Joint Surgery, 2007
- Prosthetic-Joint InfectionsThe New England journal of medicine, 2004
- Biofilm Formation: A Clinically Relevant Microbiological ProcessClinical Infectious Diseases, 2001