A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer
Authors:
- Lynn J VerheyLVLynn J Verhey
- Ping XiaPXPing Xia
- 26 March 2007
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (8) , 2147-2156
Abstract
The aim of this study is to investigate the feasibility of using conventional jaws to deliver inverse planned intensity-modulated radiotherapy (IMRT) plans for patients with prostate cancer. For ten patients, each had one three-dimensional conformal plan (3D plan) and seven inverse IMRT plans using direct aperture optimization. For IMRT plans using conventional jaws (JO plans), the number of apertures per beam angle was set from two to seven while three apertures per beam angle were set for the multi-leaf collimator (MLC) plans. To evaluate each planning method, we compared average dose volume histograms (DVH), the conformal index (COIN), total number of segments and total number of monitor units. Among the JO plans with the number of apertures per beam angle varying from two to seven, no difference was observed in the average DVHs, and the plan conformal index became saturated after four apertures per beam angle. Subsequently, JO plans with four apertures per beam angle (JO-4A) were compared with 3D and MLC plans. Based on the average DVHs, no difference was found among 3D, JO-4A and MLC plans with regard to the planning target volume and rectum, but the DVHs for the bladder and penile bulb were significantly better with inverse IMRT plans than those with 3D plans. When compared with the plan conformity, the average COIN values for 3D, JO-4A and MLC plans were 0.61 +/- 0.07, 0.73 +/- 0.05 and 0.83 +/- 0.05, respectively. In conclusion, inverse IMRT plans using conventional jaws are clinically feasible, achieving better plan quality than 3D-CRT plans.Keywords
This publication has 10 references indexed in Scilit:
- Jaws‐only IMRT using direct aperture optimizationMedical Physics, 2006
- Investigating the fundamentals of IMRT decomposition using ten simple collimator modelsPhysics in Medicine & Biology, 2006
- Constrained segment shapes in direct-aperture optimization for step-and-shoot IMRTMedical Physics, 2006
- Comparative efficiency of the multi-leaf collimator and variable-aperture collimator in intensity-modulated radiotherapyPhysics in Medicine & Biology, 2006
- Intensity-modulated radiation therapy using a variable-aperture collimatorPhysics in Medicine & Biology, 2003
- Direct aperture optimization: A turnkey solution for step‐and‐shoot IMRTMedical Physics, 2002
- Intensity-modulated radiation therapy using only jaws and a maskPhysics in Medicine & Biology, 2002
- Forward or inversely planned segmental multileaf collimator IMRT and sequential tomotherapy to treat multiple dominant intraprostatic lesions of prostate cancer to 90 GyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001
- Intensity‐modulation radiotherapy using independent collimators: An algorithm studyMedical Physics, 1999
- A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1998