Continuous millimeter-wave TUNNETT diode system for inspection applications
- 1 September 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21622027,p. 414
Abstract
We have fabricated tunneling transit time (TUNNETT) diode with fundamental-mode oscillation in the frequency up to 706 GHz. Some inspection applications have been demonstrated using the feature of TUNNETT as predominant stability of the power and the frequency. The microanalysis of albumin bovine has been performed at pico-mole level. This method has been applied to detect the sugar levels in serum. A scanning millimeter-wave imaging has been demonstrated for an inspection of human liver tissue containing cancer cells with a special resolution at 0.3 mm.Keywords
This publication has 1 reference indexed in Scilit:
- T-ray imagingIEEE Journal of Selected Topics in Quantum Electronics, 1996