Reduced Field-of-View Diffusion Imaging of the Human Spinal Cord: Comparison with Conventional Single-Shot Echo-Planar Imaging
Open Access
- 31 March 2011
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 32 (5) , 813-820
Abstract
BACKGROUND AND PURPOSE: DWI of the spinal cord is challenging because of its small size and artifacts associated with the most commonly used clinical imaging method, SS-EPI. We evaluated the performance of rFOV spinal cord DWI and compared it with the routine fFOV SS-EPI in a clinical population. MATERIALS AND METHODS: Thirty-six clinical patients underwent 1.5T MR imaging examination that included rFOV SS-EPI DWI of the cervical spinal cord as well as 2 comparison diffusion sequences: fFOV SS-EPI DWI normalized for either image readout time (low-resolution fFOV) or spatial resolution (high-resolution fFOV). ADC maps were created and compared between the methods by using single-factor analysis of variance. Two neuroradiologists blinded to sequence type rated the 3 DWI methods, based on susceptibility artifacts, perceived spatial resolution, signal intensity–to-noise ratio, anatomic detail, and clinical utility. RESULTS: ADC values for the rFOV and both fFOV sequences were not statistically different (rFOV: 1.01 ± 0.18 × 10−3 mm2/s; low-resolution fFOV: 1.12 ± 0.22 × 10−3 mm2/s; high-resolution fFOV: 1.10 ± 0.21 × 10−3 mm2/s; F = 2.747, P > .05). The neuroradiologist reviewers rated the rFOV diffusion images superior in terms of all assessed measures (P < 0.0001). Particular improvements were noted in patients with metal hardware, degenerative disease, or both. CONCLUSIONS: rFOV DWI of the spinal cord overcomes many of the problems associated with conventional fFOV SS-EPI and is feasible in a clinical population. From a clinical standpoint, images were deemed superior to those created by using standard fFOV methods.Keywords
This publication has 44 references indexed in Scilit:
- A diffusion tensor imaging group study of the spinal cord in multiple sclerosis patients with and without T2 spinal cord lesionsJournal of Magnetic Resonance Imaging, 2009
- Anisotropic field-of-view shapes for improved PROPELLER imagingMagnetic Resonance Imaging, 2009
- Role of Diffusion MRI in Diagnosis of Spinal Cord Infarction in ChildrenNeuropediatrics, 2008
- High b‐value q‐space diffusion‐weighted MRI of the human cervical spinal cord in vivo: Feasibility and application to multiple sclerosisMagnetic Resonance in Medicine, 2008
- Readout-segmented EPI for rapid high resolution diffusion imaging at 3TEuropean Journal of Radiology, 2008
- Reduced field‐of‐view MRI using outer volume suppression for spinal cord diffusion imagingMagnetic Resonance in Medicine, 2007
- Applications of diffusion-weighted MRI in thoracic spinal cord injury without radiographic abnormalityInternational Orthopaedics, 2006
- Diffusion Tensor Imaging of the Spinal CordAnnals of the New York Academy of Sciences, 2005
- Diffusion-weighted MRI and the evaluation of spinal cord axonal integrity following injury and treatmentExperimental Neurology, 2003
- ADC mapping of the human optic nerve: Increased resolution, coverage, and reliability with CSF‐suppressed ZOOM‐EPIMagnetic Resonance in Medicine, 2001