High Frequency Audiometry and Chronic Renal Failure
Author:
- Pedro Lui Bianca Simone ZeigelboimPZPedro Lui Bianca Simone Zeigelboim
- 1 January 2001
- journal article
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 121 (2) , 245-248
Abstract
High frequency audiometry with pure tones from 9 to 18 kHz was performed in 37 patients with chronic renal failure undergoing conservative medical treatment and in a control group of 96 patients (age range 30 59 years for both groups). It was noted that the high frequency thresholds were significantly higher for the patients with chronic renal disease, and further deterioration of hearing function was observed at the examination performed after 1 year of follow-up. It was concluded that high frequency audiometry is a sensitive method for detecting hearing changes in patients with chronic renal failure and can be used to monitor these patients.Keywords
This publication has 3 references indexed in Scilit:
- Electrophysiologic analysis of auditory, vestibular and brain stem function in chronic renal failureThe Laryngoscope, 1982
- Renal Disease: Its Pathology, Treatment, and Effects on the EarJAMA Otolaryngology–Head & Neck Surgery, 1980
- HEREDITARY FAMILIAL CONGENITAL HAEMORRHAGIC NEPHRITISBMJ, 1927