Wide area impedance-based fault location using synchronized/unsynchronized current measurements
- 1 December 2020
- journal article
- research article
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (12)
Abstract
Global positioning system (GPS) as an advanced technology provides synchronized measurements through the network. In spite of enhancing measurement accuracy provided by GPS, losing its signal, using slow communication link for measurement or lack of essential infrastructure for synchronized sampling make the synchronized measurement unavailable across the grid. In these conditions some fault location algorithms are not applicable and some others eliminate the corresponding measurements in their fault location process. However valuable information lies in the eliminated measurements magnitude which can improve the fault location accuracy. In this paper a system of equations is developed based on magnitudes of all current measurements and phase angle of synchronized current measurements. Then it is solved using an iterative approach with the aim of finding the location of the fault. To obtain more accurate results the distributed parameter model of line is used. The proposed method is validated by WSCC 9 bus and IEEE 39 bus test systems. The results reveal accurate estimation even in conditions that the synchronized measurements are not available in the grid entirely.Keywords
This publication has 43 references indexed in Scilit:
- Robust fault location of transmission lines by synchronised and unsynchronised wide‐area current measurementsIET Generation, Transmission & Distribution, 2014
- A closed-form solution for transmission line fault location using local measurements at a remote substationElectric Power Systems Research, 2014
- An Efficient PMU-Based Fault-Location Technique for Multiterminal Transmission LinesIEEE Transactions on Power Delivery, 2014
- New Fault-Location Method for a Single Multiterminal Transmission Line Using Synchronized Phasor MeasurementsIEEE Transactions on Power Delivery, 2006
- Accurate Location of Faults on Power Transmission Lines With Use of Two-End Unsynchronized MeasurementsIEEE Transactions on Power Delivery, 2006
- Fault Location Scheme for a Multi-Terminal Transmission Line Using Synchronized Voltage MeasurementsIEEE Transactions on Power Delivery, 2005
- Fault Location on a Transmission Line Using Synchronized Voltage MeasurementsIEEE Transactions on Power Delivery, 2004
- Fault Location in Transmission Lines Using One-Terminal Postfault Voltage DataIEEE Transactions on Power Delivery, 2004
- A digital fault-location algorithm taking into account the imaginary part of the grounding impedance at the fault placeIEEE Transactions on Power Delivery, 2003
- A practical fault location approach for double circuit transmission lines using single end dataIEEE Transactions on Power Delivery, 2003