The Importance of Modeling Press‐Fit to Accurately Evaluate Interfacial Micromotion as an Indicator of Primary Stability in Uncemented Arthroplasty
Open Access
- 9 October 2025
- journal article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (2)
Abstract
Arthroplasty is most often performed to alleviate pain and restore function in patients with end‐stage degenerative joint disease. Uncemented implant fixation is increasingly used in total knee and total ankle arthroplasty. Implantation using interference press‐fit is a manufacturer‐recommended guideline for achieving stable primary fixation in uncemented applications, which is important to prevent long‐term implant failure due to aseptic loosening. However, when evaluating implant–bone interfacial mechanics, many studies have not modeled press‐fit implantation. This can lead to gross underestimation of primary implant fixation stability, limiting the clinical applicability of findings. The goal of this paper is to highlight the importance of simulating press‐fit implantation when evaluating primary orthopedic implant stability using finite element analysis in uncemented arthroplasty. Experiences gained in modeling press‐fit implantation in total knee and total ankle arthroplasty by two different active research groups are shared in this context.Keywords
This publication has 48 references indexed in Scilit:
- Finite element analysis of primary stability in cementless tibial components with varying interference fitsClinical Biomechanics, 2025
- Highlights of the 2023 American Joint Replacement Registry Annual ReportArthroplasty Today, 2024
- Influence of offset on osseointegration in cementless total hip arthroplasty: A finite element studyJournal of Orthopaedic Research, 2024
- Influence of sidewall retention and interference fit in total ankle replacement on implant‐bone micromotion: A finite element studyJournal of Orthopaedic Research, 2024
- Biomechanical analysis of femoral stems in hinged total knee arthroplasty in physiological and osteoporotic boneComputer Methods and Programs in Biomedicine, 2022
- Biomechanical evaluation of total ankle arthroplasty. Part I: Joint loads during simulated level walkingJournal of Orthopaedic Research, 2020
- Biomechanical evaluation of total ankle arthroplasty. Part II: Influence of loading and fixation design on tibial bone–implant interactionJournal of Orthopaedic Research, 2020
- Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element studyArchives of orthopaedic and trauma surgery, 2016
- FE analysis of the effects of simplifications in experimental testing on micromotions of uncemented femoral knee implantsJournal of Orthopaedic Research, 2015
- Relations of mechanical properties to density and CT numbers in human boneMedical Engineering & Physics, 1995