Capillary Flow-Driven and Magnetically Actuated Multi-Use Wax Valves for Controlled Sealing and Releasing of Fluids on Centrifugal Microfluidic Platforms
Open Access
- 16 February 2022
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 13 (2) , 303
Abstract
Compact disc (CD)-based centrifugal microfluidics is an increasingly popular choice for academic and commercial applications as it enables a portable platform for biological and chemical assays. By rationally designing microfluidic conduits and programming the disc’s rotational speeds and accelerations, one can reliably control propulsion, metering, and valving operations. Valves that either stop fluid flow or allow it to proceed are critical components of a CD platform. Among the valves on a CD, wax valves that liquify at elevated temperatures to open channels and that solidify at room temperature to close them have been previously implemented on CD platforms. However, typical wax valves on the CD fluidic platforms can be actuated only once (to open or to close) and require complex fabrication steps. Here, we present two new multiple-use wax valve designs, driven by capillary or magnetic forces. One wax valve design utilizes a combination of capillary-driven flow of molten wax and centrifugal force to toggle between open and closed configurations. The phase change of the wax is enabled by heat application (e.g., a 500-mW laser). The second wax valve design employs a magnet to move a molten ferroparticle-laden wax in and out of a channel to enable reversible operation. A multi-phase numerical simulation study of the capillary-driven wax valve was carried out and compared with experimental results. The capillary wax valve parameters including response time, angle made by the sidewall of the wax reservoir with the direction of a valve channel, wax solidification time, minimum spin rate of the CD for opening a valve, and the time for melting a wax plug are measured and analyzed theoretically. Additionally, the motion of the molten wax in a valve channel is compared to its theoretical capillary advance with respect to time and are found to be within 18.75% of the error margin.Keywords
Funding Information
- Autonomous Medical Devices Incorporated (UCI project)
This publication has 23 references indexed in Scilit:
- A multiplexed immunoassay system based upon reciprocating centrifugal microfluidicsReview of Scientific Instruments, 2011
- Optically addressable single-use microfluidic valves by laser printer lithographyLab on a Chip, 2010
- Serial siphon valving for centrifugal microfluidic platformsMicrofluidics and Nanofluidics, 2009
- Electrically controlled microvalves to integrate microchip polymerase chain reaction and capillary electrophoresisLab on a Chip, 2008
- Passive flow switching valves on a centrifugal microfluidic platformSensors and Actuators B: Chemical, 2008
- Analysis and experiment of capillary valves for microfluidics on a rotating diskMicrofluidics and Nanofluidics, 2007
- Integrated siphon-based metering and sedimentation of whole blood on a hydrophilic lab-on-a-diskBiomedical Microdevices, 2007
- Multifunctional microvalves control by optical illumination on nanoheaters and its application in centrifugal microfluidic devicesLab on a Chip, 2007
- Phase Change Microvalve for Integrated DevicesAnalytical Chemistry, 2004
- Use of the pendant drop method to measure interfacial tension between molten polymersMaterials Research, 1999