RETRACTED ARTICLE: Bipolar radiofrequency ablation with four electrodes: Ex vivo liver experiments and finite element method analysis. Influence of inter-electrode distance on coagulation size and geometry
Authors:
- 4 September 2012
- journal article
- retracted article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 28 (7) , 686-697
Abstract
Purpose: The aim of this study was to develop an electrode system with simple needle electrodes which would allow a reliable and predictable ablation zone with radiofrequency ablation (RFA). Materials and methods: In the first step, four parallel electrodes (active length 3 cm, diameter 1.8 mm) were inserted in ex vivo bovine liver. A power of 50 W was applied between two pairs of electrodes for 10 min or until current shut-off due to impedance rise. In the second step, the influence of changing inter-electrode distance on coagulation size and geometry was measured. In the third step, a finite element method (FEM) analysis of the experiment was performed to better understand the experimental findings. Results: A bipolar four-electrode system with templates adjusting the inter-electrode distance was successfully developed for ex vivo experiments. A complete and reliable coagulation zone of a 3 × 2 × 2-cm block was obtained most efficiently with an inter-electrode distance of 2 cm in 5.12 ± 0.71 min. Above 2 cm, coagulation was incomplete due to a too low electric field, as demonstrated by the FEM analysis. Conclusions: The optimal inter-electrode distance of the present bipolar four-electrode system was 2 cm, allowing a reliable and predictable ablation zone in ex vivo liver. The FEM analysis correctly simulated and explained the findings in ex vivo liver. The experimental set-up may serve as a platform to gain more insight and to optimise the application of RFA by means of four or more simple needle electrodes.Keywords
This publication has 34 references indexed in Scilit:
- Low temperature of radiofrequency ablation at the target sites can facilitate rapid progression of residual hepatic VX2 carcinomaJournal of Translational Medicine, 2010
- Formulation of 3D finite elements for hepatic radiofrequency ablationInternational Journal of Modelling, Identification and Control, 2010
- Ultrasound simulation of real-time temperature estimation during radiofrequency ablation using finite element modelsUltrasonics, 2008
- Computer modeling of the combined effects of perfusion, electrical conductivity, and thermal conductivity on tissue heating patterns in radiofrequency tumor ablationInternational Journal of Hyperthermia, 2008
- A modified radiofrequency-assisted approach to right hemihepatectomyEuropean Journal of Surgical Oncology, 2006
- Improved perfusion system for bipolar radiofrequency ablation of liver: preliminary findings from a computer modeling studyPhysiological Measurement, 2006
- Hepatic radiofrequency ablation using perfusion electrodes in a pig model: Effect of the Pringle manoeuvreEuropean Journal of Surgical Oncology, 2006
- Investigation of the thermal and tissue injury behaviour in microwave thermal therapy using a porcine kidney modelInternational Journal of Hyperthermia, 2004
- Variability of Size and Shape of Necrosis Induced by Radiofrequency Ablation in Human Livers: A Volumetric EvaluationAnnals of Surgical Oncology, 2004
- Laparoscopic radiofrequency ablation of hepatic tumors: Prospective clinical evaluation of ablation size comparing two treatment algorithmsSurgical Endoscopy, 2004