Enhancing helium liquefaction efficiency with the two-section temperature-spectrum regenerative refrigeration method
Authors:
- Qiang CaoQCQiang Cao
- Ningna WangNWNingna Wang
- Pengyuan ZhaoPZPengyuan Zhao
- Zhiping WangZWZhiping Wang
- Peng LiPLPeng Li
- Qinyu ZhaoQZQinyu Zhao
- Bo WangBWBo Wang
- Zhihua GanZGZhihua Gan
Preprint
- 17 June 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
Helium liquefaction technology is essential for cooling scientific instruments and superconducting magnets. However, most small-scale liquefaction equipment suffers from low efficiency, typically achieving only 16-20 L/d with an input power of about 6 kW. Although the helium liquefaction efficiency based on the temperature-spectrum (previously named as “temperature-distributed”) refrigeration method proposed in prior work achieved a FOM (the ideal-to-studied liquefaction cycle input power ratio ) of 44.5% for two-stage regenerative cycle, substantial entropy is generated across the broad temperature span from the first-stage cold-end (around 30-60 K) to room temperature. To mitigate this loss, this paper introduces a two-section temperature-spectrum helium liquefaction method that employs two distinct working fluids to generate temperature-spectrum refrigeration power, thereby covering most of the wide temperature range from 4.2 K to room temperature. In this study, N2 and O2 are individually utilized as refrigerants in the first section, combined with 4He in the second section. Calculation results indicate that FOM rises to a peak before declining with both precooling temperature and second-section working pressure, while it monotonically increases with the working pressure of the first section. The optimal FOM reaches 66.0% (with N2) and 67.4% (with O2), which is the highest efficiency with a simple structure of two stages, representing improvements of 48.3% and 51.5% over the two‑stage method using only helium and reducing entropy generation loss by up to 59.6%. As the first innovative theoretical work employing a two‑section temperature-spectrum method, this approach is expected to substantially enhance the efficiency of small‑scale helium liquefaction systems.Keywords
This publication has 8 references indexed in Scilit:
- A Critical Review of Real Gas Effects on the Regenerative RefrigeratorsJournal of Thermal Science, 2020
- Cryocooler based helium liquefier using an active thermosiphon processCryogenics, 2020
- Reduction of real gas losses with a DC flow in the regenerator of the refrigeration cycleApplied Energy, 2019
- Numerical Investigation on a Looped Thermoacoustically-Driven Cryocooler for Natural Gas LiquefactionEnergy Procedia, 2017
- The MRI Helium Crisis: Past and FutureJournal of the American College of Radiology, 2016
- Real gas effects on the temperature profile of regeneratorsCryogenics, 2014
- Intermediate cooling from pulse tube and regenerator in a 4K pulse tube cryocoolerCryogenics, 2008
- Performances of the mixed-gases Joule–Thomson refrigeration cycles for cooling fixed-temperature heat loadsCryogenics, 2004