Application of the superconducting fault current limiter strategy to improve the fault ride-through capability of a doubly-fed induction generator–based wind energy conversion system
- 16 November 2015
- journal article
- research article
- Published by SAGE Publications in SIMULATION
- Vol. 91 (12) , 1081-1087
Abstract
The enormous demand for electricity is partially satisfied by the increased penetration of wind power generation resources. This necessitates a wind energy conversion system (WECS) to remain connected to the grid in order to maintain power system stability during grid faults. This paper proposes a superconducting fault current limiter control strategy to improve the fault ride-through (FRT) capability of a doubly-fed induction generator (DFIG)-based WECS during grid faults. The outstanding aspect of the proposed technique is that it reduces the fault current level at the stator side and suppresses the rotor inrush current during incidents of grid faults. Consequently, the oscillation in the DC-link voltage and the electromagnetic torque of the WECS are reduced to a minimum permissible limit. Therefore, the proposed strategy improves the FRT capability of the WECS. Thus, the WECS remains connected to the grid and contributes necessary power system stability during and after the grid faults. The effectiveness of the proposed strategy is studied through a time domain simulation carried out in a MATLAB/Simulink environment.Keywords
This publication has 17 references indexed in Scilit:
- Modeling, control and electromagnetic transient simulation of the doubly fed induction generator-based wind energy generation systemSIMULATION, 2013
- A comprehensive review on the grid integration of doubly fed induction generatorInternational Journal of Electrical Power & Energy Systems, 2013
- Modeling and simulation of a wind farm in the presence of power electronic devices for the enhancement of transient stabilitySIMULATION, 2013
- Advanced Control Strategy of DFIG Wind Turbines for Power System Fault Ride ThroughIEEE Transactions on Power Systems, 2011
- A Fault Ride-Through Technique of DFIG Wind Turbine Systems Using Dynamic Voltage RestorersIEEE Transactions on Energy Conversion, 2011
- Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer During Symmetrical and Asymmetrical Grid FaultsIEEE Transactions on Power Electronics, 2011
- Decoupled-DFIG Fault Ride-Through Strategy for Enhanced Stability Performance During Grid FaultsIEEE Transactions on Sustainable Energy, 2010
- Minimum-Threshold Crowbar for a Fault-Ride-Through Grid-Code-Compliant DFIG Wind TurbineIEEE Transactions on Energy Conversion, 2010
- Providing Ride-Through Capability to a Doubly Fed Induction Generator Under Unbalanced Voltage DipsIEEE Transactions on Power Electronics, 2009
- Modelling and transient stability of large wind farmsInternational Journal of Electrical Power & Energy Systems, 2003