Lactate detection by colorimetric measurement in real human sweat by microfluidic-based biosensor on flexible substrate
- 17 May 2019
- journal article
- research article
- Published by Taylor & Francis in The Journal of the Textile Institute
- Vol. 110 (12) , 1725-1732
Abstract
In this study, we describe the colorimetric detection of lactate concentration in real human sweat samples, as an indication of the performance of especially athletes, on a microfluidic device fabricated on a microfibrous nonwoven substrate comprising microfluidic channels and detection reservoirs. A narrow group (10 healthy individuals: 5 women and 5 men) within age range of 20–25 was used. The optimization and real sweat studies demonstrated that color formation on the biosensor surface is influenced not only by the enzyme, ABTS, gelatin ratios but also by many parameters such as storage conditions. Usage of real sweat samples showed that simulated samples only have limited similarity with the real samples and their contents can have a significant impact on the biosensor, in our case on color formation. To understand the response better, larger group of human subjects should be examined in detail in terms of effect of sweat properties to biosensor signal.Keywords
Funding Information
- TÜBİTAK (215M943)
This publication has 26 references indexed in Scilit:
- Chemiluminescence detection for microfluidic cloth-based analytical devices (μCADs)Biosensors and Bioelectronics, 2015
- A low cost design and fabrication method for developing a leak proof paper based microfluidic device with customized test zoneBiomicrofluidics, 2015
- Design and fabrication of a new nonwoven-textile based platform for biosensor constructionSensors and Actuators B: Chemical, 2015
- Microfluidic paper-based analytical devices fabricated by low-cost photolithography and embossing of Parafilm®Lab on a Chip, 2015
- Multiple semi-quantitative colorimetric assays in compact embeddable microfluidic cloth-based analytical device (μCAD) for effective point-of-care diagnosticMicrofluidics and Nanofluidics, 2015
- Advances in paper-based point-of-care diagnosticsBiosensors and Bioelectronics, 2014
- Microfluidic device on a nonwoven fabric: A potential biosensor for lactate detectionTextile Research Journal, 2014
- Cotton fabric-based electrochemical device for lactate measurement in salivaThe Analyst, 2014
- Exploration of microfluidic devices based on multi-filament threads and textiles: A reviewBiomicrofluidics, 2013
- Electrochemical detection of glucose from whole blood using paper-based microfluidic devicesAnalytica Chimica Acta, 2013