Wearable ballistocardiography: Preliminary methods for mapping surface vibration measurements to whole body forces
- 1 August 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2014 (1094687X) , 5172-5175
Abstract
The recent resurgence of ballistocardiogram (BCG) measurement and interpretation technologies has led to a wide range of powerful tools available for unobtrusively assessing mechanical aspects of cardiovascular health at home. Researchers have demonstrated a multitude of modern BCG measurement modalities, including beds, chairs, weighing scales, and wearable approaches. However, many modalities produce significant variations in the morphology of the measured BCG, creating confusion in the analysis and interpretation of the signals. This paper creates a framework for comparing wearable BCG measurements to whole body measurements - such as taken with a weighing scale system - to eventually allow the same analysis and interpretation tools that have been developed for whole body systems to be applied in the future to wearable systems. To the best of our knowledge, it represents the first attempt to morphologically compare vertical acceleration recordings measured on different locations on the torso to whole body displacements measured by BCG instrumentation.Keywords
This publication has 17 references indexed in Scilit:
- Preliminary results from standing ballistocardiography measurements in microgravity2013
- A preliminary study investigating the quantification of beat-to-beat in seismocardiogram signals2013
- Recent advances in cardiovascular monitoring using ballistocardiography2012
- Noninvasive Measurement of Physiological Signals on a Modified Home Bathroom ScaleIEEE Transactions on Biomedical Engineering, 2012
- A continuous, wearable, and wireless heart monitor using head ballistocardiogram (BCG) and head electrocardiogram (ECG)2011
- Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiographPhysiological Measurement, 2009
- Static‐charge‐sensitive bed ballistocardiography in cardiovascular monitoringClinical Physiology and Functional Imaging, 1996
- The Finapres 2300e finger cuffAnaesthesia, 1993
- Studies Utilizing the Portable Electromagnetic BallistocardiographCirculation, 1953
- THE CARDIAC OUTPUT IN MAN: STUDIES WITH THE LOW FREQUENCY, CRITICALLY-DAMPED BALLISTOCARDIOGRAPH, AND THE METHOD OF RIGHT ATRIAL CATHETERIZATION 1Journal of Clinical Investigation, 1947