Influence of Fracture Stability on Early Patient Mortality and Reoperation After Pertrochanteric and Intertrochanteric Hip Fractures
- 1 December 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 29 (12) , 538-543
Abstract
Objectives: To determine the influence of fracture stability on early patient mortality and complications requiring reoperation after trochanteric hip fracture. Design: Prospective consecutive cohort study. Setting: The orthopaedic unit of a public teaching hospital. Participants: Seven hundred twenty-eight patients with 743 consecutive stable (n = 446) pertrochanteric and unstable (n = 297) pertrochanteric or intertrochanteric fractures (median age: 84 years, 71% females) resulting from a low-impact injury and surgically managed. Mean follow-up of surviving patients was 4 years (range: 2–6 years). Intervention: Fracture fixation by dynamic hip screw extramedullary device or intramedullary nail (Austofix or Gamma3) based on surgeon preference. Main Outcome Measures: Mortality within 6 and 12 months and surgical complications requiring device reoperation within 12 months of surgery (multivariate logistic regression and Kaplan–Meier survival analyses). Results: Patients with unstable fractures were at 1.61 times (95% confidence interval: 1.18–2.21, P = 0.003) and 1.37 times (95% confidence interval: 1.02–1.83, P = 0.037) greater odds of dying within 6 and 12 months, respectively, than those with stable fractures. Older age, male gender, higher American Society of Anesthesiologists classification, in residential care, and inpatient-reported medical complications were also independent risk factors for early mortality. Increasing fracture instability and fixation using the Austofix nail were associated with early device reoperation. Comparable results were reported for the dynamic hip screw and Gamma3 nail, although the Gamma3 nail may offer advantages for more complex unstable fractures. Conclusions: Fracture instability influences early mortality after surgical fixation of trochanteric hip fracture. The Austofix double lag screw device had suboptimal results. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 23 references indexed in Scilit:
- Sliding hip screw versus the Targon PF nail in the treatment of trochanteric fractures of the hipThe Journal of Bone and Joint Surgery. British volume, 2012
- Evidence SummaryJournal of Bone and Joint Surgery, 2011
- External Fixation for Stable and Unstable Intertrochanteric Fractures in Patients Older Than 75 Years of Age: A Prospective Comparative StudyJournal of Orthopaedic Trauma, 2011
- Evidence‐based guidelines for the management of hip fractures in older persons: an updateMedical Journal of Australia, 2010
- A meta-analysis of the Gamma nail and dynamic hip screw in treating peritrochanteric fracturesInternational Orthopaedics, 2009
- Fracture and Dislocation Classification Compendium - 2007Journal of Orthopaedic Trauma, 2007
- Development and Initial Validation of a Risk Score for Predicting In‐Hospital and 1‐Year Mortality in Patients With Hip FracturesJournal of Bone and Mineral Research, 2005
- Importance of events per independent variable in proportional hazards regression analysis II. Accuracy and precision of regression estimatesJournal of Clinical Epidemiology, 1995
- A new mobility score for predicting mortality after hip fractureThe Journal of Bone and Joint Surgery. British volume, 1993
- GRADING OF PATIENTS FOR SURGICAL PROCEDURESAnesthesiology, 1941