Flow Imaging Microscopy for Protein Particle Analysis—A Comparative Evaluation of Four Different Analytical Instruments
Authors:
- 31 August 2013
- journal article
- research article
- Published by Springer Nature in The AAPS Journal
- Vol. 15 (4) , 1200-1211
Abstract
Flow imaging microscopy was introduced as a technique for protein particle analysis a few years ago and has strongly gained in importance ever since. The aim of the present study was a comparative evaluation of four of the most relevant flow imaging microscopy systems for biopharmaceuticals on the market: Micro-Flow Imaging (MFI)4100, MFI5200, Flow Cytometer And Microscope (FlowCAM) VS1, and FlowCAM PV. Polystyrene standards, particles generated from therapeutic monoclonal antibodies, and silicone oil droplets were analyzed by all systems. The performance was critically assessed regarding quantification, characterization, image quality, differentiation of protein particles and silicone oil droplets, and handling of the systems. The FlowCAM systems, especially the FlowCAM VS1, showed high-resolution images. The FlowCAM PV system provided the most precise quantification of particles of therapeutic monoclonal antibodies, also under impaired optical conditions by an increased refractive index of the formulation. Furthermore, the most accurate differentiation of protein particles and silicone oil droplets could be achieved with this instrument. The MFI systems provided excellent size and count accuracy (evaluated with polystyrene standards) especially the MFI5200 system. This instrument also showed very good performance for protein particles, also in case of an increased refractive index of the formulation. Both MFI systems were easier to use and appeared more standardized regarding measurement and data analysis as compared to the FlowCAM systems. Our study shows that the selection of the appropriate flow imaging microscopy system depends strongly on the main output parameters of interest and it is recommended to decide based on the intended application.Keywords
This publication has 20 references indexed in Scilit:
- Micro–Flow Imaging and Resonant Mass Measurement (Archimedes) – Complementary Methods to Quantitatively Differentiate Protein Particles and Silicone Oil DropletsJournal of Pharmaceutical Sciences, 2013
- How Subvisible Particles Become Invisible—Relevance of the Refractive Index for Protein Particle AnalysisJournal of Pharmaceutical Sciences, 2013
- Flow Imaging: Moving Toward Best Practices for Subvisible Particle Quantitation in Protein ProductsJournal of Pharmaceutical Sciences, 2013
- Quantification and Characterization of Micrometer and Submicrometer Subvisible Particles in Protein Therapeutics by Use of a Suspended Microchannel ResonatorAnalytical Chemistry, 2012
- Discrimination Between Silicone Oil Droplets and Protein Aggregates in Biopharmaceuticals: A Novel Multiparametric Image Filter for Sub-visible Particles in Microflow Imaging AnalysisPharmaceutical Research, 2011
- Quantification and Characterization of Subvisible Proteinaceous Particles in Opalescent mAb Formulations Using Micro-Flow ImagingJournal of Pharmaceutical Sciences, 2010
- Quantitation of protein particles in parenteral solutions using micro-flow imagingJournal of Pharmaceutical Sciences, 2009
- Overlooking Subvisible Particles in Therapeutic Protein Products: Gaps That May Compromise Product QualityJournal of Pharmaceutical Sciences, 2009
- Weighing of biomolecules, single cells and single nanoparticles in fluidNature, 2007
- Effects of protein aggregates: An immunologic perspectiveThe AAPS Journal, 2006