The XFM beamline at the Australian Synchrotron
Open Access
- 19 August 2020
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (5) , 1447-1458
Abstract
The X-ray fluorescence microscopy (XFM) beamline is an in-vacuum undulator-based X-ray fluorescence (XRF) microprobe beamline at the 3 GeV Australian Synchrotron. The beamline delivers hard X-rays in the 4–27 keV energy range, permitting K emission to Cd and L and M emission for all other heavier elements. With a practical low-energy detection cut-off of approximately 1.5 keV, low-Z detection is constrained to Si, with Al detectable under favourable circumstances. The beamline has two scanning stations: a Kirkpatrick–Baez mirror microprobe, which produces a focal spot of 2 µm × 2 µm FWHM, and a large-area scanning `milliprobe', which has the beam size defined by slits. Energy-dispersive detector systems include the Maia 384, Vortex-EM and Vortex-ME3 for XRF measurement, and the EIGER2 X 1 Mpixel array detector for scanning X-ray diffraction microscopy measurements. The beamline uses event-mode data acquisition that eliminates detector system time overheads, and motion control overheads are significantly reduced through the application of an efficient raster scanning algorithm. The minimal overheads, in conjunction with short dwell times per pixel, have allowed XFM to establish techniques such as full spectroscopic XANES fluorescence imaging, XRF tomography, fly scanning ptychography and high-definition XRF imaging over large areas. XFM provides diverse analysis capabilities in the fields of medicine, biology, geology, materials science and cultural heritage. This paper discusses the beamline status, scientific showcases and future upgrades.Keywords
This publication has 50 references indexed in Scilit:
- Natural gold particles in Eucalyptus leaves and their relevance to exploration for buried gold depositsNature Communications, 2013
- Reconstructing state mixtures from diffraction measurementsNature, 2013
- High-Definition X-ray Fluorescence Elemental Mapping of PaintingsAnalytical Chemistry, 2012
- Caenorhabditis elegans Maintains Highly Compartmentalized Cellular Distribution of Metals and Steep Concentration Gradients of ManganesePLOS ONE, 2012
- Hard X-ray fluorescence tomography—an emerging tool for structural visualizationCurrent Opinion in Structural Biology, 2010
- Silicon nitride as a versatile growth substrate for microspectroscopic imaging and mapping of individual cellsMolecular BioSystems, 2010
- Multimodal x-ray scatter imagingNew Journal of Physics, 2009
- Contrast mechanisms in scanning transmission x-ray microscopyPhysical Review A, 2009
- An assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopyJournal of Electron Spectroscopy and Related Phenomena, 2009
- Quantitative Phase Imaging with a Scanning Transmission X-Ray MicroscopePhysical Review Letters, 2008