Tendon Multiscale Structure, Mechanics, and Damage Are Affected by Osmolarity of Bath Solution
Authors:
- 30 October 2020
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (3) , 1058-1068
Abstract
One of the most common bath solutions used in musculoskeletal mechanical testing is phosphate buffered saline (PBS). In tendon, swelling induced by physiological PBS results in decreased tendon modulus and induces microstructural changes. It is critical to evaluate the multiscale mechanical behavior of tendon under swelling to interpret prior work and provide information to design future studies. We compared the effects of physiological PBS and 8% polyethylene glycol and saline bathing solutions on tendon multiscale tendon mechanics and damage as well as microstructure with TEM in order to understand the effect of swelling on tendon. At the tissue level, tendons in PBS had a lower modulus than SPEG samples. PBS samples also showed an increased amount of non-recoverable sliding, which is an analog for microscale damage. SPEG had a higher microscale to tissue-scale strain ratio, showing the fibrils experienced less strain attenuation. From the TEM data, we showed the fibril spacing of SPEG samples was more similar to fresh control than PBS. We concluded that swelling alters multiscale mechanics and damage in addition to tendon microstructure. Future mechanical testing should consider using SPEG as a bath solution with an osmotic pressure which preserves fresh tissue water content.Keywords
Funding Information
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR070966)
- National Institute of General Medical Sciences (P20GM103446)
This publication has 30 references indexed in Scilit:
- Fiji: an open-source platform for biological-image analysisNature Methods, 2012
- Multi-scale Structural and Tensile Mechanical Response of Annulus Fibrosus to Osmotic LoadingAnnals of Biomedical Engineering, 2012
- Relationship between solute transport properties and tissue morphology in human annulus fibrosusJournal of Orthopaedic Research, 2009
- Effect of dermatan sulfate glycosaminoglycans on the quasi‐static material properties of the human medial collateral ligamentJournal of Orthopaedic Research, 2007
- The influence of swelling and matrix degradation on the microstructural integrity of tendonActa Biomaterialia, 2006
- The Influence of Noncollagenous Matrix Components on the Micromechanical Environment of Tendon FasciclesAnnals of Biomedical Engineering, 2005
- Effect of cyclic and static tensile loading on water content and solute diffusion in canine flexor tendons: An in Vitro studyJournal of Orthopaedic Research, 1994
- Influence of cyclic loading on the nutrition of articular cartilage.Annals of the Rheumatic Diseases, 1990
- Swelling of articular cartilage and other connective tissues: Electromechanochemical forcesJournal of Orthopaedic Research, 1985
- The intermolecular space of reconstituted collagen fibrilsJournal of Molecular Biology, 1973