High‐resolution peripheral vein bypass graft wall studies using high sampling efficiency inner volume 3D FSE
Open Access
- 24 January 2008
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 59 (3) , 650-654
Abstract
A 3D inner‐volume fast spin echo (3D IV‐FSE) sequence was developed for ECG‐gated, black‐blood, T1‐ and T2‐weighted vessel wall imaging of peripheral vein bypass grafts (PVBG). The sequence utilizes nonselective refocusing excitations to minimize echo spacings and a highly selective IV excitation scheme to minimize the need for oversampling of z‐encode slice selections. The method was tested in eight PVBG patients who also underwent 2D FSE graft imaging. High‐quality 3D imaging was achieved in all subjects, with significant spatial resolution and volume coverage gains compared to the more conventional 2D FSE sequences normalized for signal‐to‐noise ratios (SNRs) and scan times. Compared to previously proposed 3D IV‐FSE methods, nonselective refocusing resulted in a more than 20% FSE echo train sampling efficiency increase while the use of highly selective IV excitation resulted in a 30% improvement in slice oversampling efficiency. Magn Reson Med, 2008.Keywords
This publication has 19 references indexed in Scilit:
- High-resolution 3D arteriography of chronic total peripheral occlusions using aT1-W turbo spin-echo sequence with inner-volume imagingMagnetic Resonance in Medicine, 2006
- Evaluation of carotid artery wall volume measurement using novel semiautomated analysis softwareJournal of Magnetic Resonance Imaging, 2006
- MRI of atherosclerosis in clinical trialsNMR in Biomedicine, 2006
- Characterization of Human Atherosclerotic Plaques by Intravascular Magnetic Resonance ImagingCirculation, 2005
- Effective blood signal suppression using double inversion-recovery and slice reordering for multislice fast spin-echo MRI and its application in simultaneous proton density and T2 weighted imagingJournal of Magnetic Resonance Imaging, 2004
- Volume‐selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurementJournal of Magnetic Resonance Imaging, 2003
- Vascular Endothelium, Hemodynamic Forces, and AtherogenesisThe American Journal of Pathology, 1999
- Monitoring Functional Patency of Percutaneous Transluminal AngioplastyArchives of Surgery, 1991
- Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging)IEEE Transactions on Medical Imaging, 1991
- Carotid bifurcation atherosclerosis. Quantitative correlation of plaque localization with flow velocity profiles and wall shear stress.Circulation Research, 1983