An automatic lamp detection technique for electronic ballasts
Authors:
- 1 January 2005
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 575-581
Abstract
Based on a comprehensive comparison of fluorescent lamp parameters of major lamp manufacturers, this paper presents an automatic lamp power detection method that can differentiate the lamp power of tubular T8 and T12 fluorescent lamps. This method can be easily incorporated into existing electronic ballast control so that the same electronic ballast design can operate different lamps at their respective rated power levels. With this patented method, a universal electronic ballast can be designed to operate the full range of T8 and T12 fluorescent lamps from 18 W to 70 W without any power mismatch problem. Design criteria and practical verifications are included to confirm the theory behind this lamp power detection method.Keywords
This publication has 4 references indexed in Scilit:
- Parameter Monitoring of High-Frequency Electronically Operated Discharge Lamp SystemsIEEE Transactions on Power Electronics, 2005
- Self excited half-bridge series resonant parallel loaded fluorescent lamp electronic ballasts2002
- Modelling of a high-frequency operatedfluorescent lamp in an electronic ballastenvironmentIEE Proceedings - Science, Measurement and Technology, 1998
- Analysis of self-excited electronic ballasts using BJTs/MOSFETs as switching devicesIEE Proceedings - Circuits, Devices and Systems, 1998