Abstract
OBJECTIVE. The purpose of this study is to compare the diagnostic accuracy of liver apparent diffusion coefficient (ADC) versus normalized liver ADC using the spleen as a reference organ for the diagnosis of liver fibrosis and cirrhosis.MATERIALS AND METHODS. Fifty-six patients, 34 with liver disease and 22 control subjects, were assessed with breath-hold single-shot echo-planar diffusion-weighted imaging using b values of 0, 50, and 500 s/mm2. Liver ADC and normalized liver ADC (defined as the ratio of liver ADC to spleen ADC) were compared between patients stratified by fibrosis stage. Receiver operating characteristic (ROC) analysis was used to determine the performance of ADC and normalized liver ADC for prediction of liver fibrosis and cirrhosis. Reproducibility was assessed by measuring coefficient of variation (n = 7).RESULTS. Liver ADC failed to distinguish individual stages of fibrosis, except between stages 0 and 4. There were significant differences in normalized liver ADC between control liver...

This publication has 33 references indexed in Scilit: