Transbrachial insertion of a 7.5-Fr intra-aortic balloon pump in a severely atherosclerotic patient*
Authors:
- Francesco OnoratiFrancesco Onorati
- Massimo BilottaMBMassimo Bilotta
- Francesco PezzoFPFrancesco Pezzo
- Barbara ImpiombatoBIBarbara Impiombato
- Santo CaroleoSCSanto Caroleo
- Ermenegildo SantangeloESErmenegildo Santangelo
- Attilio RenzulliARAttilio Renzulli
- 1 August 2006
- journal article
- case report
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 34 (8) , 2231-2233
Abstract
Preoperative intra-aortic balloon pumping (IABP) improves the results of complex coronary surgery. However, its insertion may be harmful or contraindicated in cases of severe and diffuse atherosclerosis of the descending aorta and peripheral arteries. We sought to evaluate the efficacy and safety of transbrachial insertion of the new 7.5-Fr IABP to support a severely ill patient with eggshell distal aorta and femoro-iliac arteries undergoing coronary artery bypass grafting (CABG). Case report. An 18-bed adult cardiac surgery unit at a university hospital. A 68-yr-old man with ongoing unstable angina, left main disease, and eggshell calcification in the abdominal aorta and iliaco-femoral arteries, needing IABP for CABG. Percutaneous sheathless right transbrachial insertion of 7.5-Fr IABP, followed by CABG. Fluoroscopy and chest radiograph were used to confirm the exact position of the IABP, in the preoperative and postoperative time, respectively. A digital pulse oximeter was applied to monitor distal perfusion. Anticoagulation consisted of nadroparin 4000 IU daily until the second postoperative day, followed by 150 mg of aspirin daily thereafter. Transbrachial IABP support allowed uneventful CABG and postoperative course, without IABP-related complications. Pulse oximetry demonstrated constant good values, the radial artery pulse was always present, and the hand appeared constantly warm. IABP was withdrawn 20 hrs following surgery, and the patient was discharged home on the ninth postoperative day. The miniaturization of IABP, with the recent introduction of a 7.5-Fr balloon catheter, opens the door for the safe, effective transbrachial method of insertion in patients with severe peripheral atherosclerosis.Keywords
This publication has 13 references indexed in Scilit:
- Comparison of outcomes after 8 vs. 9.5 French size intra-aortic balloon counterpulsation catheters based on 9,332 patients in the prospective Benchmark® registryCatheterization and Cardiovascular Interventions, 2002
- The current practice of intra-aortic balloon counterpulsation: results from the Benchmark RegistryJACC, 2001
- A Decade’s Experience With Quality Improvement in Cardiac Surgery Using the Veterans Affairs and Society of Thoracic Surgeons National DatabasesAnnals of Surgery, 2001
- Preoperative intraaortic balloon pumps in high-risk patients undergoing open heart surgeryThe Annals of Thoracic Surgery, 2001
- Associated vascular lesions in patients undergoing coronary artery bypass graftingActa Cardiologica, 2001
- A novel technique for intraaortic balloon pump placement via the left axillary artery in patients awaiting cardiac transplantationCardiovascular Surgery, 2000
- Optimal timing of preoperative intraaortic balloon pump support in high-risk coronary patientsThe Annals of Thoracic Surgery, 1999
- Preoperative Intraaortic Balloon Pump Enhances Cardiac Performance and Improves the Outcome of Redo CABGThe Annals of Thoracic Surgery, 1997
- Intraaortic balloon pumping for cardiac support: Trends in practice and outcome, 1968 to 1995The Journal of Thoracic and Cardiovascular Surgery, 1997
- Transthoracic intraaortic balloon pump: A simplified techniqueThe Annals of Thoracic Surgery, 1996