Separation and Quantification of Two Fluoroquinolones in Serum by On-Line High-Performance Immunoaffinity Chromatography
- 4 August 2000
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (17) , 4148-4153
Abstract
To demonstrate that two structurally similar chemicals can be extracted from a complex matrix and then separated from each other on the basis of their relative affinities for an antibody, an automated column-switching system was used, incorporating on-line, high-performance immunoaffinity chromatography (HPIAC). A high-affinity monoclonal antibody (Mab Sara-95) against the fluoroquinolone sarafloxacin was covalently cross-linked to a protein G column and used to capture fluoroquinolones in fortified serum samples. Interference from matrix components adhering nonspecifically to the column was minimized by the insertion of a protein G cleanup column between the injection port and the Mab Sara-95 derivatized HPIAC column. Upon injection, serum samples containing the fluoroquinolones passed through both columns. The cleanup column detained serum components, that otherwise would bind nonspecifically to the HPIAC column, but allowed the fluoroquinolones to pass through unhindered to the HPIAC column. The fluoroquinolones were then eluted from the HPIAC column according to their relative affinities for the antibody, and individual peaks were monitored using fluorescence detection. By using an on-line cleanup column in tandem with an HPIAC column, the fluoroquinolones could be separated from the serum matrix and then separated from each other on the basis of their affinity for Mab Sara-95 without the use of organic solvents or reversed-phase liquid chromatography (RPLC). This method demonstrates true immunoaffinity separation of structurally related compounds in a complex matrix.Keywords
This publication has 21 references indexed in Scilit:
- Capillary ElectrophoresisAnalytical Chemistry, 1999
- Strategies in Using Analytical Restricted Access Media Columns for the Removal of Humic Acid Interferences in the Trace Analysis of Acidic Herbicides in Water Samples by Coupled Column Liquid Chromatography with UV DetectionAnalytical Chemistry, 1999
- On-Line Immunoaffinity Capture, Coupled with HPLC and Electrospray Ionization Mass Spectrometry, for Automated Determination of FumonisinsJournal of Agricultural and Food Chemistry, 1998
- Production and Characterization of Monoclonal Antibodies against Sarafloxacin and Cross-Reactivity Studies of Related FluoroquinolonesJournal of Agricultural and Food Chemistry, 1997
- Characterization of Benzodiazepine “Combinatorial” Chemical Libraries by On-Line Immunoaffinity Extraction, Coupled Column HPLC−Ion Spray Mass Spectrometry−Tandem Mass SpectrometryAnalytical Chemistry, 1996
- Characterization of monoclonal antibodies to aflatoxin M1 and molecular modeling studies of related aflatoxinsMolecular Immunology, 1996
- Characterization of monoclonal anti-furosemide antibodies and molecular modeling studies of cross-reactive compoundsMolecular Immunology, 1994
- Non-Selective Desorption of Immuno Precolumns Coupled On-Line with Column Liquid Chromatography: Determination of AflatoxinsInternational Journal of Environmental Analytical Chemistry, 1991
- Application of immunoassay in the food industryCritical Reviews in Food Science and Nutrition, 1991
- Dual-column immunoassays using protein G affinity chromatographyAnalytical Chemistry, 1989