Air Sentinel: An IoT-Based Platform for Monitoring Indoor Air Quality in Elementary Schools of the Global South
Authors:
- Salvador Ruiz-CorreaSRSalvador Ruiz-Correa
- Rubén López-RevillaRLRubén López-Revilla
- Lina Riego-RuizLRLina Riego-Ruiz
- Gladys DíazGDGladys Díaz
- Khaled BoussettaKBKhaled Boussetta
- Nicolás Gómez-HernándezNGNicolás Gómez-Hernández
- Abdulhalim DandoushAbdulhalim Dandoush
- Lamine AmourLALamine Amour
- Francisco Marmolejo-CossíoFMFrancisco Marmolejo-Cossío
- Marco Aurelio Cárdenas-JuárezMCMarco Aurelio Cárdenas-Juárez
- Janeth Gabriela Rivera-AguilarJRJaneth Gabriela Rivera-Aguilar
Preprint
- 23 December 2025
- preprint
- Published by Springer Nature in Research Square
Abstract
Indoor air quality (IAQ) is neglected in schools of the Global South. Carbon dioxide (CO 2 ) and particulate matter (PM 2.5 ) are indicators of ventilation and exposure risk to airborne infections, respectively. We deployed Air Sentinel , a decentralized mobile-driven IoT network, to monitor these indicators across 106 spaces in 53 elementary schools in the San Luis Potosí Metropolitan Area, Mexico. Machine learning was used to forecast CO 2 and PM 2.5 concentrations one hour in advance, and the Wells-Riley model, based on CO 2 concentration, to estimate airborne infection probability (AIP). IAQ was poor, acceptable, and excellent in 27.3%, 36.4%, and 67.2% of the classrooms, respectively. During the cold season, 97.67% of the classroom CO 2 levels were typical (400–1000 ppm); in the hot season, 67.67% of the classroom CO 2 levels were typical, and 1.19% exceeded the high exposure threshold (> 2000 ppm). Classroom CO 2 dynamics exhibited low temporal synchrony. The strongest forecasting performance for CO 2 occurred in the hot season, but the PM 2.5 forecast failed in either season while AIP increased during the first two hours of class in both seasons. The successful CO 2 forecasting model has potential for real-time IAQ management in the cold season. The failure to forecast PM 2.5 levels suggests that localized sources drive their dynamics. We conclude that the Air Sentinel network is a convenient classroom IAQ monitor in the Global South.Keywords
All Related Versions
This publication has 45 references indexed in Scilit:
- Influence of seasonal variation on spatial distribution of PM2.5 concentration using low-cost sensorsEnvironmental Monitoring and Assessment, 2024
- Effect of Indoor Air Quality on Respiratory Health of Children: An MPPD Model ApproachAerosol Science and Engineering, 2024
- Bayesian optimization + XGBoost based life cycle carbon emission prediction for residential buildings—An example from Chengdu, ChinaBuilding Simulation, 2023
- Quantifying indoor PM2.5 levels and its sources in schools: What role does location, chalk use, and socioeconomic equity play ?Atmospheric Pollution Research, 2022
- Natural ventilation in classrooms for healthy schools in the COVID era in Mediterranean climateBuilding and Environment, 2021
- Exposure routes and health effects of heavy metals on childrenBioMetals, 2019
- Development and comparison of regression models and feedforward backpropagation neural network models to predict seasonal indoor PM2.5–10 and PM2.5 concentrations in naturally ventilated schoolsAtmospheric Pollution Research, 2015
- Multivariate methods for indoor PM10 and PM2.5 modelling in naturally ventilated schools buildingsAtmospheric Environment, 2014
- Applied Predictive Modeling2013
- Proximity Analysis for Exposure Assessment in Environmental Health Justice Research2011