Effect of Pattern Layout and Dissolved Oxygen in CO2 Rinse Water on Cu Corrosion during Post-Etch Cleaning
Authors:
- Kentaro TokuriKTKentaro Tokuri
- Yukinari YamashitaYYYukinari Yamashita
- Morio ShioharaMSMorio Shiohara
- Noriaki OdaNONoriaki Oda
- Seiichi KondoSKSeiichi Kondo
- Shuichi SaitoSSShuichi Saito
- 1 May 2010
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 49 (5S2) , 05FF04
Abstract
When post-etch cleaning was carried out in Cu dual-damascene process, Cu at the bottom of isolated via was etched out especially in the wafer edge, and this would become a critical issue as device scale is shrunk. The corrosion was caused in the rinse step rather than chemical cleaning step because dissolved oxygen in rinse water from the air increased oxidation–reduction potential (ORP) and CO2 included in the rinse water for preventing wafer electrification decreased pH. The corrosion was found to be suppressed by increasing dummy pattern density and by controlling atmosphere and pH of the rinse water.Keywords
This publication has 2 references indexed in Scilit:
- Effect of Dissolved Oxygen on Cu Corrosion in Single Wafer Cleaning ProcessJapanese Journal of Applied Physics, 2009
- Influence of Post-CMP Cleaning on Cu Interconnects and TDDB ReliabilityIEEE Transactions on Electron Devices, 2005