Varus malalignment of short femoral stem not associated with post-hip arthroplasty fracture
- 30 November 2021
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (11) , 3533-3538
Abstract
Introduction Periprosthetic femoral fractures are an increasingly common post-operative complication of total hip arthroplasty (THA). Though varus malalignment is known to increase fracture risk in standard-length femoral stems, varus malalignment is not as well studied in short stems. Therefore, the purpose of this study was to determine if varus malalignment contributes to early periprosthetic fracture risk in a cementless taper-wedged, short femoral stem. Materials and methods This retrospective review included 366 consecutive patients (441 THAs) having undergone THA via anterior approach by a single surgeon between July 2014 and December 2016. All patients received the same short, cementless femoral stem. Femoral component angle was measured on 6-week post-THA weight-bearing radiographs, with malalignment defined as a femoral component angle exceeding 0° ± 3°. Periprosthetic femoral fracture and aseptic loosening occurring within 2 years post-THA were recorded. Results The final data analysis included 426 hips with a mean follow-up time of 32.9 ± 10.2 months. Varus and neutral alignment occurred in 84 (19.6%) and 342 (79.9%) of stems, respectively. Three (0.7%) periprosthetic femoral fractures occurred within 2 years, all occurring in patients with neutrally aligned femoral stems. One (0.2%) stem failed due to aseptic loosening and was malaligned. Conclusion Despite nearly 20% of stems placed in varus alignment, three of the four early complications occurred in a neutrally aligned stem. Based on these results, forceful intraoperative realignment of a short femoral stem with good initial fixation may present an unnecessary increased risk of intraoperative fracture.Keywords
This publication has 39 references indexed in Scilit:
- Surgeons changing the approach for total hip arthroplasty from posterior to direct anterior with fluoroscopy should consider potential excessive cup anteversion and flexion implantation of the stem in their early experienceInternational Orthopaedics, 2015
- Short Bone-Conserving Stems in Cementless Hip ArthroplastyJournal of Bone and Joint Surgery, 2014
- Early Failures in Total Hip Arthroplasty — A Changing ParadigmThe Journal of Arthroplasty, 2014
- The Rationale for Short Uncemented Stems in Total Hip ArthroplastyOrthopedic Clinics of North America, 2014
- Femoral Lateral Bowing and Varus Condylar Orientation Are Prevalent and Affect Axial Alignment of TKA in KoreansClinical Orthopaedics and Related Research, 2013
- Twelve-Year Risk of Revision After Primary Total Hip Replacement in the U.S. Medicare PopulationJournal of Bone and Joint Surgery, 2012
- A Short Tapered Stem Reduces Intraoperative Complications in Primary Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2012
- Biomechanical reconstruction of the hip: comparison between modular short-stem hip arthroplasty and conventional total hip arthroplastyInternational Orthopaedics, 2012
- Periprosthetic Fractures: Epidemiology and Future ProjectionsJournal of Orthopaedic Trauma, 2011
- The Effect of Stem Alignment on Results of Total Hip Arthroplasty with a Cementless Tapered-Wedge Femoral ComponentThe Journal of Arthroplasty, 2008