Quality assessment of blood glucose testing in general practitioners’ offices improves quality
Authors:
- Marta StahlMSMarta Stahl
- Steffen IversenSISteffen Iversen
- Jens Anton FiltenborgJFJens Anton Filtenborg
Open Access
- 1 October 1997
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 43 (10) , 1926-1931
Abstract
Measurement of blood glucose is a frequent test in Danish physicians’ offices. We describe here a new design of external quality assessment wherein fresh, unstabilized whole-blood samples were analyzed by the physicians’ office methods and by a hospital laboratory comparison method (glucose dehydrogenase assay, calibrated against NIST 909a). This approach was used in the offices of 171 general practitioners in our county during a 5-year period. The first survey, in 1992, revealed unsatisfactory performance in terms of our criterion that no difference between the physician’s office and the hospital laboratory’s single result should exceed ±20% of the laboratory result. After initiation of a program of consultation and assistance, the proficiency testing rounds of 1994 and 1996 showed considerable improvement. Thus, whereas in 1992 12% of the values were outside the acceptance limits, in 1994 and 1996 the respective values were 4% and 3%. We believe the effect was mainly related to improvements in choice of technology, procedures, and handling of specimens. We conclude that the use of bedside instruments should be restricted to diagnosis of only severe hypo- or hyperglycemia and to monitoring glucose >5 mmol/L in already diagnosed diabetics. Our program differs from previous approaches to quality assessment and could also be useful for large hospitals’ in-house proficiency testing.Keywords
This publication has 8 references indexed in Scilit:
- Tests of Glycemia in DiabetesDiabetes Care, 1997
- International normalized ratio for prothrombin times in patients taking oral anticoagulants: critical difference and probability of significant change in consecutive measurementsClinical Chemistry, 1995
- Patient and Physician Analytic Goals for Self-Monitoring Blood Glucose InstrumentsAmerican Journal of Clinical Pathology, 1994
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusThe New England journal of medicine, 1993
- Desirable standards for laboratory tests if they are to fulfill medical needsClinical Chemistry, 1993
- 10. Vocabulary for Describing the Metrological Quality of a Measurement ProcedureUpsala Journal of Medical Sciences, 1993
- Five-Year Follow-Up Study on Plasma Insulin Levels in Newly Diagnosed NIDDM Patients and Nondiabetic SubjectsDiabetes Care, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986