Optimal energy‐based seismic design of non‐conventional Tuned Mass Damper (TMD) implemented via inter‐story isolation
Authors:
Top Cited Papers
- 20 January 2015
- journal article
- research article
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 44 (10) , 1623-1642
Abstract
Summary: Inter‐story isolation, an effective strategy for mitigating the seismic risk of both new and existing buildings, has gained more and more interest in recent years as alternative to base isolation, whenever the latter results to be impractical, technically difficult or uneconomic. As suggested by the name, the technique consists in inserting flexible isolators at floor levels other than the base along the height of a multi‐story building, thus realizing a non‐conventional Tuned Mass Damper (TMD). Consistent with this, an optimal design methodology is developed in the present paper with the objective of achieving the global protection of both the structural portions separated by the inter‐story isolation system, that is, the lower portion (below the isolation system) and the isolated upper portion (above the isolation system). The optimization procedure is formulated on the basis of an energy performance criterion that consists in maximizing the ratio between the energy dissipated in the isolation system and the input energy globally transferred to the entire structure. Numerical simulations, performed under natural accelerograms with different frequency content and considering increasing isolation levels along the height of a reference frame structure, are used to investigate the seismic performance of the optimized inter‐story isolation systems. Copyright © 2015 John Wiley & Sons, Ltd.Keywords
Funding Information
- AXA Research Fund (Continuity of essential services in the face of earthquake emergency)
This publication has 27 references indexed in Scilit:
- Optimal design of an equipment isolation system with nonlinear hysteretic behaviourEarthquake Engineering & Structural Dynamics, 2013
- An alternative methodology for designing tuned mass dampers to reduce seismic vibrations in building structuresEarthquake Engineering & Structural Dynamics, 2012
- Analysis and Design of Inter-Story Isolation Systems with Nonlinear DevicesJournal of Earthquake Engineering, 2010
- Semi‐active tuned mass damper building systems: ApplicationEarthquake Engineering & Structural Dynamics, 2009
- Semi‐active tuned mass damper building systems: DesignEarthquake Engineering & Structural Dynamics, 2009
- Slide roof system for dynamic response reductionEarthquake Engineering & Structural Dynamics, 2008
- Optimum parameters of tuned mass damper for damped main systemStructural Control and Health Monitoring, 2006
- A METHOD OF ESTIMATING THE PARAMETERS OF TUNED MASS DAMPERS FOR SEISMIC APPLICATIONSEarthquake Engineering & Structural Dynamics, 1997
- Reduction seismic response with heavily-damped vibration absorbersEarthquake Engineering & Structural Dynamics, 1985
- Optimum absorber parameters for various combinations of response and excitation parametersEarthquake Engineering & Structural Dynamics, 1982