A study of various parameters of spherically curved phased arrays for noninvasive ultrasound surgery
Authors:
- Kullervo HynynenKHKullervo Hynynen
- 1 April 1996
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 41 (4) , 591-608
Abstract
The spherically curved square element phased array design for ultrasound surgery was studied in several of its important aspects. A method for determining the spatial limitations of the multiple-foci region was developed for spherically curved phased arrays. The effects on the ultrasound fields of varying the phases and the amplitudes at control points were investigated. It was found that the phases and the magnitudes of control points have an impact on the ultrasound field distributions. The effects of multiple-foci spacing, pulse duration, and maximum temperature on the size and shape of necrosed tissue were investigated. For a spherically curved phased array with an 8 cm radius of curvature, an 8.8 x 8.8 cm2 projected area, and a 1.5 MHz operating frequency, the minimum number of phased array elements that could produce the largest acceptable necrosed tissue volume was 256. The tissue volume necrosed during the sonication could be increased to approximately 1 x 1 x 3 cm3 with this array.Keywords
This publication has 14 references indexed in Scilit:
- Control of the necrosed tissue volume during noninvasive ultrasound surgery using a 16‐element phased arrayMedical Physics, 1995
- The effects of curved tissue layers on the power deposition patterns of therapeutic ultrasound beamsMedical Physics, 1994
- Focal spacing and near-field heating during pulsed high temperature ultrasound therapyUltrasound in Medicine & Biology, 1993
- The effect of wave reflection and refraction at soft tissue interfaces during ultrasound hyperthermia treatmentsThe Journal of the Acoustical Society of America, 1992
- A spherical-section ultrasound phased array applicator for deep localized hyperthermiaIEEE Transactions on Biomedical Engineering, 1991
- Optimization of the intensity gain of multiple-focus phased-array heating patternsInternational Journal of Hyperthermia, 1991
- Effects of physical parameters on high temperature ultrasound hyperthermiaUltrasound in Medicine & Biology, 1990
- A cylindrical-section ultrasound phased-array applicator for hyperthermia cancer therapyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1988
- A Tapered Phased Array Ultrasound Transducer for Hyperthermia TreatmentIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1987
- Concentric-Ring and Sector-Vortex Phased-Array Applicators for Ultrasound HyperthermiaIEEE Transactions on Microwave Theory and Techniques, 1986