Amniotic Fluid Embolism: Early Findings of Transesophageal Echocardiography
Authors:
- Avishai ZiserAZAvishai Ziser
- Robert MarkovitsRMRobert Markovits
- Beno RozenbergBRBeno Rozenberg
- 1 December 1999
- journal article
- case report
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 89 (6) , 1456-8
Abstract
Mniotic fluid embolism (AFE) is a rare event, but one that is responsible for approximately 10% of all maternal deaths (1). Regardless of treatment, it is associated with a very high mortality rate (2). While approximately 70% of maternal deaths caused by AFE are a result of cardiopulmonary collapse (3), the pathophysiology of the cardiopulmonary distur- bance is not clearly understood. Almost all human hemodynamic data post-AFE were collecte d1ho r more after the event (4), yet 25%-50% of the parturi- ents die within the first hour of clinical presentation (5,6). We present a case in which transesophageal echocardiography (TEE) was performed during the early course of AFE. The TEE findings provide addi- tional information regarding the cardiopulmonary pathophysiology occurring during the very early phase of AFE.Keywords
This publication has 4 references indexed in Scilit:
- Amniotic fluid embolism causing severe left ventricular dysfunction and death: Case report and review of the literatureCatheterization and Cardiovascular Diagnosis, 1996
- New Concepts of Amniotic Fluid EmbolismObstetrical & Gynecological Survey, 1990
- Arachidonic Acid Metabolites and the Pathophysiology of Amniotic Fluid EmbolismSeminars in Reproductive Medicine, 1985
- AMNIOTIC FLUID EMBOLISMObstetrical & Gynecological Survey, 1974