Optimisation of CT scan parameters to increase the accuracy of gross tumour volume identification in brain radiotherapy
- 15 June 2020
- journal article
- research article
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 20 (3) , 340-344
Abstract
Aim: This study aimed to optimise computed tomography (CT) simulation scan parameters to increase the accuracy for gross tumour volume identification in brain radiotherapy. For this purpose, high-contrast scan protocols were assessed.Materials and methods: A CT accreditation phantom (ACR Gammex 464) was used to optimise brain CT scan parameters on a Toshiba Alexion 16-row multislice CT scanner. Dose, tube voltage, tube current–time and CT dose index (CTDI) were varied to create five image quality enhancement (IQE) protocols. They were assessed in terms of contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and noise level and compared with a standard clinical protocol. Finally, the ability of the selected protocols to identify low-contrast objects was examined based on a subjective method.Results: Among the five IQE protocols, the one with the highest tube current–time product (250 mA) and lowest tube voltage (100 kVp) showed higher CNR, while another with a tube current–time product of 150 mA and a tube voltage of 135 kVp had improved SNR and lower noise level compared to the standard protocol. In contouring low-contrast objects, the protocol with the highest milliampere and lowest peak kilovoltage exhibited the lowest error rate (1%) compared to the standard protocol (25%).Findings: CT image quality should be optimised using the high-dose parameters created in this study to provide better soft tissue contrast. This could lead to an accurate identification of gross tumour volume recognition in the planning of radiotherapy treatment.Keywords
This publication has 32 references indexed in Scilit:
- Automatic CT simulation optimization for radiation therapy: A general strategyMedical Physics, 2014
- SU-E-J-35: Imaging Dose in Radiotherapy: An Institution-Based StudyMedical Physics, 2013
- Effect of Tube Voltage on CT Noise Levels in Different Phantom SizesAmerican Journal of Roentgenology, 2013
- Dose-Length Product to Effective Dose Conversion Factors for Common Computed Tomography Examinations Based on Canadian Clinical ExperienceCanadian Association of Radiologists Journal, 2013
- High‐dose MVCT image guidance for stereotactic body radiation therapyMedical Physics, 2012
- Optimizing CT Dose and Image Quality for Radiotherapy PatientsJournal of the American College of Radiology, 2012
- Clinical target volume delineation in glioblastomas: pre-operative versus post-operative/pre-radiotherapy MRIBritish Journal of Radiology, 2011
- The management of imaging dose during image‐guided radiotherapy: Report of the AAPM Task Group 75Medical Physics, 2007
- Image quality preferences among radiographers and radiologists. A conjoint analysisRadiography, 2005
- Tradeoffs between image quality and dosePediatric Radiology, 2004