Variations in pulmonary artery occlusion pressure to estimate changes in pleural pressure
- 31 August 2007
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 33 (11) , 2004-2008
Abstract
Objective A readily available assessment of changes in pleural pressure would be useful for ventilator and fluid management in critically ill patients. We examined whether changes in pulmonary artery occlusion pressure (Ppao) adequately reflect respiratory changes in pleural pressure as assessed by changes in intraesophageal balloon pressure (Peso). We studied patients who had a pulmonary catheter and esophageal balloon surrounding a nasogastric tube as part of their care (n = 24). We compared changes in Ppao (dPpao) to changes in Peso (dPeso) by Bland–Altman and regression analysis. Adequacy of balloon placement was assessed by performing Mueller maneuvers and adjusting the position to achieve a ratio of dPeso to change in tracheal pressure (dPtr) of 0.85 or higher. This was achieved in only 14 of the 24 subjects. We also compared dCVP to dPeso. The dPpao during spontaneous breaths and positive pressure breaths gave a good estimate of Peso but generally underestimated dPeso (bias = 2.2 +8.2 and –3.9 cmH2O for the whole group). The dCVP was not as good a predictor (bias = 2.9 +10.3 and –4.6). In patients who have a pulmonary artery catheter in place dPpao gives a lower estimate of changes in pleural pressure and may be more reliable than dPeso. The dCVP is a less reliable predictor than changes in pleural pressure.Keywords
This publication has 26 references indexed in Scilit:
- Use of the Pulmonary Artery CatheterSeminars in Respiratory and Critical Care Medicine, 1999
- Respiratory variations in right atrial pressure predict the response to fluid challengeJournal of Critical Care, 1992
- Noncardiogenic Pulmonary Edema following Upper Airway Obstruction 7 Cases and a Review of the LiteratureMedicine, 1991
- Acute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical VentilationAnesthesiology, 1988
- Quartz crystal microbalance measurements of absolute laser photodeposition rates: Application to 257-nm deposition from W(CO)6Journal of Applied Physics, 1987
- Measurement of Pleural Pressure with Esophageal Balloon in Anesthetized HumansAnesthesiology, 1983
- Effects of negative pleural pressure on left ventricular hemodynamicsThe American Journal of Cardiology, 1983
- Effect of Intrathoracic Pressure on Left Ventricular PerformanceNew England Journal of Medicine, 1979
- A comparison of central venous pressure and pleural pressure in supine dogsRespiration Physiology, 1977
- Alveolar Pressure, Pulmonary Venous Pressure, and the Vascular WaterfallRespiration, 1962