Noniterative compensation for the distance-dependent detector response and photon attenuation in SPECT imaging
Authors:
- C.L. ByrneCBC.L. Byrne
- 1 June 1994
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 13 (2) , 363-374
Abstract
A filtering approach is described, which accurately compensates for the 2D distance-dependent detector response, as well as for photon attenuation in a uniform attenuating medium. The filtering method is based on the frequency distance principle (FDP) which states that points in the object at a specific source-to-detector distance provide the most significant contribution to specified frequency regions in the discrete Fourier transform (DFT) of the sinogram. By modeling the detector point spread function as a 2D Gaussian function whose width is dependent on the source-to-detector distance, a spatially variant inverse filter can be computed and applied to the 3D DFT of the set of all sinogram slices. To minimize noise amplification the inverse filter is rolled off at high frequencies by using a previously published Wiener filter strategy. Attenuation compensation is performed with Bellini's method. It was observed that the tomographic point response, after distance-dependent filtering with the FDP, was approximately isotropic and varied substantially less with position than that obtained with other correction methods. Furthermore, it was shown that processing with this filtering technique provides reconstructions with minimal degradation in image fidelity.<>Keywords
This publication has 18 references indexed in Scilit:
- The effect of intrinsic attenuation correction methods on the stationarity of the 3-D modulation transfer function of SPECTMedical Physics, 1992
- Restoration of combined conjugate images in SPECT: comparison of a new Wiener filter and the image-dependent Metz filterIEEE Transactions on Nuclear Science, 1990
- Relative importance of the error sources in Wiener restoration of scintigramsIEEE Transactions on Medical Imaging, 1990
- Fourier Method For Correction Of Depth-Dependent Collimator Blurring1989
- Correction Of Collimator Aperture Using A Shift-Variant Deconvolution Filter In Gamma Camera Emission CT1988
- The circular harmonic transform for SPECT reconstruction and boundary conditions on the Fourier transform of the sinogramIEEE Transactions on Medical Imaging, 1988
- A quantitative comparison of attenuation-weighted backprojection with multiplicative and iterative postprocessing attenuation compensation in SPECTIEEE Transactions on Medical Imaging, 1988
- Novel Properties Of The Fourier Decomposition Of The Sinogram1986
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1979
- Compensation of tissue absorption in emission tomographyIEEE Transactions on Acoustics, Speech, and Signal Processing, 1979