Randomized study of the safety and clinical utility of rotational vs. standard coronary angiography using a flat-panel detector
- 1 September 2005
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 66 (1) , 43-49
Abstract
The purpose of this study was to test the hypothesis that rotational angiography improves patient safety while maintaining diagnostic accuracy for patients undergoing coronary angiography. Despite advances in angiographic technique, patients remain at risk for complications of coronary angiography, including contrast‐induced nephropathy and radiation exposure. Technology has been developed to perform coronary angiography with active rotation of the imaging system that may reduce the quantity of contrast and radiation to which the patient is exposed. Fifty patients undergoing diagnostic cardiac catheterization were randomized to either standard vs. rotational angiography of the coronary arteries using a prespecified protocol with a flat‐panel single‐plane imaging system. We measured the quantity of radiographic contrast utilized and radiation exposure. Using an intention‐to‐treat analysis, there was a 40% reduction (24 ± 5 vs. 40 ± 10 ml; P < 0.0001) in contrast utilization in the rotational group compared to the standard group. Neither radiation exposure (35 ± 14 vs. 30 ± 20 Gycm2; P = 0.35), fluoroscopic time (44 ± 33 vs. 44 ± 40 sec; P = 0.99), nor procedure time (249 ± 137 vs. 214 ± 79 sec; P = 0.26) differed, although significant intraoperator variability was noted for both standard and rotational angiography. The radiation exposure using this flat‐panel system is significantly lower than prior reports that used an image intensifier system. Rotational coronary angiography has the potential to improve patient safety by markedly reducing radiographic contrast exposure while maintaining comparable diagnostic accuracy, radiation exposure, and procedure time compared to standard coronary angiography.Keywords
This publication has 7 references indexed in Scilit:
- ACCF/AHA/HRS/SCAI Clinical Competence Statement on Physician Knowledge to Optimize Patient Safety and Image Quality in Fluoroscopically Guided Invasive Cardiovascular ProceduresCirculation, 2005
- Rotational X‐ray coronary angiographyCatheterization and Cardiovascular Interventions, 2004
- Randomized study of the safety and clinical utility of rotational angiography versus standard angiography in the diagnosis of coronary artery diseaseCatheterization and Cardiovascular Interventions, 2004
- Contrast Nephropathy After Coronary AngiographyMayo Clinic Proceedings, 2004
- Usefulness of rotational spin for coronary angiography in patients with advanced renal insufficiencyThe American Journal of Cardiology, 2002
- American College of Cardiology/Society for Cardiac Angiography and Interventions Clinical Expert Consensus Document on Cardiac Catheterization Laboratory Standards41When citing this document, the American College of Cardiology and the Society for Cardiac Angiography and Interventions would appreciate the following citation format: Bashore TM, Bates ER, Berger PB, Clark DA, Cusma JT, Dehmer GJ, Kern MJ, Laskey WK, O’Laughlin MP, Oesterle S, Popma JJ. Cardiac catheterization laboratory standards: a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents (ACC/SCA&I Committee to Develop an Expert Consensus Document on Cardiac Catheterization Laboratory Standards). J Am Coll Cardiol 2001;37:2170–214.44Address for reprints: This document is available on the Web sites of the American College of Cardiology (http://www.acc.org) and the Society for Cardiac Angiography and Interventions (http://www.scai.org). Reprints of this document may be purchased for $5 each by calling 1-800-253-4636, ext 694, or by writing to the American College of Cardiology, Educational Services, 9111 Old Georgetown Road, Bethesda, MD 20814-1699.JACC, 2001
- Panoramic Coronary AngiographyJACC, 1998