The roles of multileaf collimators and micro-multileaf collimators in conformal and conventional nasopharyngeal carcinoma radiotherapy treatments
Authors:
- Peter Ho Keung ChoiPCPeter Ho Keung Choi
- Ricky Ming Chun ChauRCRicky Ming Chun Chau
- Louis Kit Yee LeeLLLouis Kit Yee Lee
- Peter Man Lung TeoPTPeter Man Lung Teo
- Yuen Kan NgarYNYuen Kan Ngar
- 1 October 1999
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 26 (10) , 2077-2085
Abstract
The purpose of this work is to study the efficacy and limitations of using standard multileaf collimators (MLCs) and micro-multileaf collimators (mMLCs) in the treatment of nasopharyngeal carcinoma (NPC) by conventional and conformal radiotherapy techniques. The penumbra characteristics of MLC, mMLC, and customized block collimated beams are measured with respect to leaf edge angle, beam energy, treatment depth, and field size and compared with those generated by a commercial three-dimensional planning computer system. Upon verification of the planning system, it is used to evaluate the treatment plans generated with these beam shapers for conventional and conformal NPC treatments. The effective penumbra of a MLC beam is strongly influenced by its edge angle, leaf width, and treatment depth. The suitability of standard MLCs in conventional NPC treatments is determined mainly by the edge angle to be used. For conformal NPC treatments involving six or more fields, dose volume histograms comparable to those of customized beam blocks are obtained with a standard MLC. The mMLC does not have the same restrictions as those on standard MLC but is limited to phase II treatment by its small usable field size. Both standard MLCs and mMLCs can be used to replace customized divergent beam blocks in both conventional and conformal NPC treatments. However, a MLC, due to its larger effective penumbra, may be unsuitable for use in cases when the tumor volumes extend very close to the critical normal structures. A mMLC, on the other hand, is limited by its small maximum field size and can only be used for collimating the facial portals in the second phase treatment.Keywords
This publication has 16 references indexed in Scilit:
- Physical characteristics of a miniature multileaf collimatorMedical Physics, 1999
- American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: Quality assurance for clinical radiotherapy treatment planningMedical Physics, 1998
- Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived from basic beam dataPhysics in Medicine & Biology, 1996
- Effects of treatment setup variation on beam's eye view dosimetry for radiation therapy using the multileaf collimator vs. the cerrobend blockInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995
- Multifeaf collimation versus alloy blocks: Analysis of geometric accuracyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995
- Characterization of a multileaf collimator systemInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993
- Initiation of multileaf collimator conformal radiation therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993
- The use of a multi-leaf collimator for conformal radiotherapy of carcinomas of the prostate and nasopharynxInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993
- Pitfalls in the use of high energy X rays to treat tumors in the lungInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1990
- The influence of the size of the grid used for dose calculation on the accuracy of dose estimationMedical Physics, 1989