A high-performance liquid chromatographic method has been developed for the separation and quantification of chrysin and synthetic chrysin derivatives (12 chrysin alkyl and 7 chrysin acyl derivatives). The chromatography was performed using a Nova-Pak® C18 column. A RP-HPLC was performed by using a binary mixture (MeOH-10 mM H3P04) as a mobile phase, and the column temperature was maintained at room temperature. A flow rate was 1.0 ml/min, and the effluent was monitored at a wavelenth of 280 nm. The retention times for chrysin acyl and alkyl derivatives were within 10 minutes and 20 minutes, respectively. The absolute recovery of samples were all over 96%. The detection limits were 0.1~18 ng at S/N = 3 ratio.Keywords
This publication has 4 references indexed in Scilit:
- Identification of lipophilic flavonols by a combination of chromatographic and spectral techniquesPhytochemical Analysis, 1995
- Variations in the lipophilic and vacuolar flavonoids of the genus VelloziaPhytochemistry, 1994
- High-performance liquid chromatography of 34 selected flavonoidsJournal of Chromatography A, 1982
- Analysis of phenolic acids and flavonoids by high-pressure liquid chromatographyJournal of Chromatography A, 1976