GTac-SE: A Low-Density Intention Sensing for Forearm Exoskeleton With Shear Force Sensors
- 19 November 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (2) , 2963-2977
Abstract
This study explores the use of GTac-SE shear force sensors for detecting forearm rotation in upper-limb assistive exoskeletons for patients with arm weakness. The purpose is to evaluate these sensors as a reliable alternative to conventional methods, like EMG and IMUs, in real-world scenarios. Methods involved two experiments comparing GTac-SE sensors with EMG and IMUs. The first experiment assessed their ability to detect small forearm rotations mimicking weak patient motions, while the second evaluated sensor robustness during proximal joint (elbow) motions. Results showed that EMG struggled to detect subtle forearm rotations due to signal overlap between movement and rest, whereas IMUs and shear force sensors performed better. EMG was also sensitive to proximal joint movements, making intention detection difficult. While IMU gyroscopes displayed clear motion patterns, they were affected by other body movements, leading to unreliable joint angle estimations. In contrast, GTac-SE sensors, housed in a brace designed to isolate forearm rotation, outperformed both EMG and IMUs. GTac-SE signals were consistent across subjects with minimal interference during elbow flexion/extension. Additionally, GTac-SE required only simple moving-average filtering, while EMG and IMU signals needed complex filtering. In conclusion, GTac-SE shear force sensors provide a direct, reliable, and practical solution for intention sensing in daily-use exoskeletons. They outperform EMG and IMUs, particularly in scenarios where multi-joint tasks are required for patients with weak arms.Keywords
This publication has 46 references indexed in Scilit:
- Occluded Gait reconstruction in multi person Gait environment using different numerical methodsMultimedia Tools and Applications, 2022
- HDL-PSR: Modelling Spatio-Temporal Features Using Hybrid Deep Learning Approach for Post-Stroke RehabilitationNeural Processing Letters, 2022
- Hand gesture recognition based on motor unit spike trains decoded from high-density electromyographyBiomedical Signal Processing and Control, 2020
- Perspectives on Euler angle singularities, gimbal lock, and the orthogonality of applied forces and applied momentsMultibody System Dynamics, 2018
- Wearable Technology in Medicine and Health Care2018
- EMG onset detection and upper limb movements identification algorithmMicrosystem Technologies, 2014
- Successful feed-forward strategies following ACL injury and reconstructionJournal of Electromyography and Kinesiology, 2009
- Development of a 3DOF mobile exoskeleton robot for human upper-limb motion assistRobotics and Autonomous Systems, 2008
- ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion—Part II: shoulder, elbow, wrist and handJournal of Biomechanics, 2005
- Scapular kinematics: effects of altering the Euler angle sequence of rotationsJournal of Biomechanics, 2000