Factors influencing chromatographic data in fast gas chromatography with on‐column injection
- 20 December 2002
- journal article
- Published by Wiley in Journal of Separation Science
- Vol. 25 (18) , 1325-1331
Abstract
The use of larger volume injection with on‐column injection and fast GC commercial instrumentation was evaluated with the model mixture of n‐alkanes of a broad range of volatility (C10–C28). The presented configuration allows introduction of 40–80‐fold larger sample volumes without any distortion of peak shapes compared to “usual” fast GC set‐ups using narrow‐bore columns. A normal‐bore retention gap (1–5 m×0.32 mm ID) was coupled to a narrow‐bore (5 m×0.1 mm ID×0.4 μm film thickness) analytical column using a standard press‐fit connector. The connection was tight and reliable, and hence suitable for hydrogen as carrier gas. The effect of pre‐column and analytical column connector, injection volume, pre‐column length, column inlet pressure, and analyte volatility on peak shape, peak broadening, and focusing are discussed. The precision of chromatographic data measurements and peak capacity under optimised temperature programmed conditions for fast separations with large volume injection were found to be very good. The presented fast GC set‐up with on‐column injection extends the applicability of the technique to trace analysis.Keywords
This publication has 18 references indexed in Scilit:
- Practical fast gas chromatography: methods, instrumentation and applicationsTrAC Trends in Analytical Chemistry, 2002
- Evaluation of time-of-flight mass spectrometric detection for fast gas chromatographyJournal of Chromatography A, 2000
- Strategies for speed optimisation in gas chromatography: an overviewJournal of Chromatography A, 1999
- Peer Reviewed: High-speed gas chromatographyAnalytical Chemistry, 1998
- Valve injection for gas chromatographic analysis on small-bore open tubular columnsJournal of Microcolumn Separations, 1996
- High‐speed gas chromatography using an on‐column thermal desorption modulatorJournal of Microcolumn Separations, 1989
- Considerations on Speed of Separation, Detection, and Identification Limits in Capillary GC and GC/MSC R C Critical Reviews in Analytical Chemistry, 1988
- Fast analysis by gas chromatographyChromatographia, 1982
- Speed of analysis in open tubular column gas chromatographyAnalytical Chemistry, 1978
- Influence of instrumental contributions on the apparent column efficiency in high speed gas chromatographyAnalytical Chemistry, 1978