Fundamental limits of light-wave sensing for non-contact respiration monitoring
- 21 October 2024
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (11) , 6449-6468
Abstract
An experimental testbed was constructed to rigorously assess the fundamental limits of light-wave sensing—an economic, non-contact vitals monitoring approach previously reported. We improve the testbed using lock-in amplification and demonstrate that a photodetector and a commonplace array of infrared LEDs are sufficient to detect respiratory motion and quantify respiration rate up to 2.5 meters away. We propose a novel scattering model, from which we derive the performance limits of the light-wave sensing system in terms of a theoretical range resolution limited by the dynamic range of the system. Using a robotic breathing phantom, we experimentally assess, for the first time, the range resolution of the testbed system and compare this to theoretical predictions. This work also introduces a process for generating stochastic respiration patterns, which may prove broadly useful to the designers of breathing phantoms. Holistically exploring practical challenges and analytical models, this paper serves as a unique and comprehensive tutorial for understanding and designing light-wave sensing systems.Keywords
All Related Versions
Funding Information
- National Science Foundation (2008556)
This publication has 24 references indexed in Scilit:
- Contactless Respiration Monitoring Using Wi-Fi and Artificial Neural Network Detection MethodIEEE Journal of Biomedical and Health Informatics, 2023
- Monitoring Respiratory Motion With Wi-Fi CSI: Characterizing Performance and the BreatheSmart AlgorithmIEEE Access, 2022
- Non-Contact Respiratory Monitoring Using an RGB Camera for Real-World ApplicationsSensors, 2021
- Relationships between respiratory muscle strength, chest wall expansion, and functional capacity in healthy nonsmokersJournal of Exercise Rehabilitation, 2020
- The effects of awareness and count duration on adult respiratory rate measurements: An experimental studyJournal of Clinical Nursing, 2017
- Toward a Robust Estimation of Respiratory Rate From Pulse OximetersIEEE Transactions on Biomedical Engineering, 2016
- An Ultrasonic Contactless Sensor for Breathing MonitoringSensors, 2014
- CMOS Optoelectronic Lock-In Amplifier With Integrated Phototransistor ArrayIEEE Transactions on Biomedical Circuits and Systems, 2010
- Missed opportunities? An observational study of vital sign measurementsCritical Care and Resuscitation, 2008
- Breathing Movements and Breathing Patterns among Healthy Men and Women 20–69 Years of AgeRespiration, 2006