Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software
Open Access
- 1 January 2016
- journal article
- research article
- Published by Wiley in Journal of Ophthalmology
- Vol. 2016, 1-7
Abstract
Purpose.To evaluate the repeatability and reproducibility of quantitative analysis of the morphological corneal changes after orthokeratology treatment using “Image-Pro Plus 6.0” software (IPP).Methods.Three sets of measurements were obtained: two sets by examiner 1 with 5 days apart and one set by examiner 2 on the same day. Parameters of the eccentric distance, eccentric angle, area, and roundness of the corneal treatment zone were measured using IPP. The intraclass correlation coefficient (ICC) and repetitive coefficient (COR) were used to calculate the repeatability and reproducibility of these three sets of measurements.Results.ICC analysis suggested “excellent” reliability of more than 0.885 for all variables, and COR values were less than 10% for all variables within the same examiner. ICC analysis suggested “excellent” reliability for all variables of more than 0.90, and COR values were less than 10% for all variables between different examiners. All extreme values of the eccentric distance and area of the treatment zone pointed to the same material number in three sets of measurements.Conclusions. IPP could be used to acquire the exact data of the characteristic morphological corneal changes after orthokeratology treatment with good repeatability and reproducibility. This trial is registered with trial registration number:ChiCTR-IPR-14005505.Keywords
Funding Information
- National Natural Science Foundation of China (81200716)
This publication has 20 references indexed in Scilit:
- A simple spot test quantification method to determine formaldehyde in aqueous samplesJournal of Saudi Chemical Society, 2016
- Vertical and Horizontal Thickness Profiles of the Corneal Epithelium and Bowman's Layer after OrthokeratologyInvestigative Ophthalmology & Visual Science, 2013
- A study of diffusion of dyes in model foods using a visual methodJournal of Food Engineering, 2012
- Long-term Changes in Corneal Morphology Induced by Overnight OrthokeratologyCurrent Eye Research, 2011
- Monitoring Cellulase Protein Adsorption and Recovery Using SDS-PAGEIndustrial & Engineering Chemistry Research, 2010
- Local Steepening in Peripheral Corneal Curvature After Corneal Refractive Therapy and LASIKOptometry and Vision Science, 2010
- Influence of induced decentered orthokeratology lens on ocular higher-order wavefront aberrations and contrast sensitivity functionJournal of Cataract & Refractive Surgery, 2009
- Topographical evaluation of centration of excimer laser myopic photorefractive keratectomyJournal of Cataract & Refractive Surgery, 1994
- Centration of excimer laser photorefractive keratectomy relative to the pupilJournal of Cataract & Refractive Surgery, 1993
- Topographical analysis of the centration of excimer laser photorefractive keratectomyJournal of Cataract & Refractive Surgery, 1993