Rapid microbial identification and colistin resistance detection via MALDI-TOF MS using a novel on-target extraction of membrane lipids
Open Access
- 9 December 2020
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-9
Abstract
Rapid infection diagnosis is critical to improving patient treatment and outcome. Recent studies have shown microbial lipids to be sensitive and selective biomarkers for identifying bacterial and fungal species and antimicrobial resistance. Practical procedures for microbial lipid biomarker analysis will therefore improve patient outcomes and antimicrobial stewardship. However, current lipid extraction methods require significant hands-on time and are thus not suited for direct adoption as a clinical assay for microbial identification. Here, we have developed a method for lipid extraction directly on the surface of stainless-steel matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) plates, termed fast lipid analysis technique or FLAT, which facilitates the identification of bacterial and fungal species using a sub-60-minute workflow. Additionally, our method detects lipid A modifications in Gram-negative bacteria that are associated with antimicrobial resistance, including to colistin.Keywords
Funding Information
- National Institute of Allergy and Infectious Diseases (R01AI147314)
- National Institute of General Medical Sciences (R01GM111066)
- European Regional Development Fund (MAB/2017/03)
This publication has 36 references indexed in Scilit:
- Unique Structural Modifications Are Present in the Lipopolysaccharide from Colistin-Resistant Strains of Acinetobacter baumanniiAntimicrobial Agents and Chemotherapy, 2013
- Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry-Based Functional Assay for Rapid Detection of Resistance against β-Lactam AntibioticsJournal of Clinical Microbiology, 2012
- Microorganism Identification Based On MALDI-TOF-MS Fingerprints2010
- Evaluation of Matrix-Assisted Laser Desorption Ionization-Time-of-Flight Mass Spectrometry in Comparison to 16S rRNA Gene Sequencing for Species Identification of Nonfermenting BacteriaJournal of Clinical Microbiology, 2008
- Unique Lipid A Modifications inPseudomonas aeruginosaIsolated from the Airways of Patients with Cystic FibrosisThe Journal of Infectious Diseases, 2007
- Structural heterogeneity and environmentally regulated remodeling of Francisella tularensis subspecies novicida lipid a characterized by tandem mass spectrometryJournal of the American Society for Mass Spectrometry, 2007
- Microextraction of bacterial lipid A: easy and rapid method for mass spectrometric characterizationJournal of Lipid Research, 2005
- Bacterial modification of LPS and resistance to antimicrobial peptidesInnate Immunity, 2001
- Lipids in the Structure and Function of Fungal Membranes1990
- SNIP, a statistics-sensitive background treatment for the quantitative analysis of PIXE spectra in geoscience applicationsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1988