Cochlear helix and duct length identification – Evaluation of different curve fitting techniques
Authors:
- 9 April 2018
- journal article
- research article
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 19 (5) , 268-283
Abstract
Objective: Within the field of cochlear implantation (CIs), the role of utilizing patient-specific cochlear anatomy for choosing the optimal implant electrode is becoming increasingly important. Unfortunately, performing detailed anatomical measurements of a cochlea using clinical imaging data is rather time consuming and hence difficult to implement into the clinical routine. In order to accelerate clinical cochlear anatomy evaluations, previously developed mathematical models can be adjusted to the patient-specific anatomy by measuring just a few overall cochlear dimensions. However, the accuracy of model-based cochlear anatomy estimations is unclear, and incorrect evaluations may lead to false conclusions regarding the suitability of specific implant electrodes. Methods: Based on 10 cochleae, an error evaluation of various commonly used curve fitting approaches for cochlear shape and duct length approximation was conducted. Spline tracings of the cochlear contours were used as reference values for the various approximations. Results: Parameterized average cochlear helix models and two of five analytical approaches were found to be suitable for reconstructing the cochlear helical shape and estimating its length. Discussion: Spline curve reconstructions are the most accurate and reliable method for assessing patient-specific cochlear geometry, especially in the case of anatomical irregularities. The most accurate results within the group of model-based evaluations still resulted in mean overall cochlear length deviations of approximately 5%. Conclusion: Spline curve reconstructions appear to be the best option for anatomical diagnostics in clinical practice. Retrospective studies can be performed to further evaluate model-based evaluations.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft
- German Research Foundation (Hearing4all)
This publication has 46 references indexed in Scilit:
- Consensus Panel on a Cochlear Coordinate System Applicable in Histologic, Physiologic, and Radiologic Studies of the Human CochleaOtology & Neurotology, 2010
- Depth of Electrode Insertion and Postoperative Performance in Humans with Cochlear Implants: A Histopathologic StudyAudiology and Neurotology, 2010
- Variational Anatomy of the Human CochleaOtology & Neurotology, 2009
- Role of Electrode Placement as a Contributor to Variability in Cochlear Implant OutcomesOtology & Neurotology, 2008
- Implications of Deep Electrode Insertion on Cochlear Implant FittingJournal of the Association for Research in Otolaryngology, 2007
- Cochlear Implantation in Patients with Substantial Residual HearingThe Laryngoscope, 2004
- Three-dimensional geometric modeling of the cochlea using helico-spiral approximationIEEE Transactions on Biomedical Engineering, 2000
- Cochlear view: Postoperative radiography for cochlear implantationAmerican Journal of Otolaryngology, 2000
- Modeling seashellsACM SIGGRAPH Computer Graphics, 1992
- Ultrastruetural Evaluation of the Microslicing Method for the Study of Temporal Bone PathologyActa Oto-Laryngologica, 1987