The sequence of tightening bolts and controlling torque are very important to the assembly of flanged pipe joint connections. Among other factors, proper-flanged joint closure depends on applying the correct amount of gasket load and achieving uniform load around the joint. Since the load applied to the joint by the bolts is difficult to measure directly, torque is used as a convenient way to approximate the desired load. This paper will review torque calculations as they apply to ANSI/AWWA C207 flanges and the new AWWA web-based interactive tool, including examples for torque calculations as described in the recently published, AWWA Manual M11, Steel Pipe—A Guide for Design and Installation, 5thEdition.