Reduction of radiation exposure in scoliosis monitoring using flat detector and pulsed fluoroscopy technology
- 30 September 2021
- journal article
- research article
- Published by Universa BV in Acta Orthopaedica Belgica
- Vol. 87 (3) , 545-552
Abstract
A new flat detector and pulsed fluoroscopy technology is available to further reduce radiation exposure in radiological monitoring during scoliosis treatment in children and adolescents. The aim of this study is to compare different settings of the system (opening area(OA) and image quality settings (IQS)) in order to find the optimal parameters with high image quality and the lowest possible radiation exposure. Therefore, we examined four cadaver spines (T1 to sacrum) with the flat detector technique using digital pulsed fluoroscopy and simulated the abdominal soft tissues. The images were merged and evaluated by three different investigators using an established scoring system. For comparison, we used digital radiography images of the cadaver spines. The values for the DAP increased from the small OA (33%; 0.56 mu Gy.m(2)) to the maximum OA (100%; 0.82 mu Gy.m(2)) by 45% (p =.003) and from the low image quality setting (0.57 mu Gy.m(2)) to the high setting (0.84 mu Gy.m(2)) by 48% (p =.028). Despite the low DAP, the setting 33% OA achieved the best point values for image quality, therefore this setting is clearly preferred. Using a digital fluoroscopy system allows a significant reduction of radiation exposure by a factor of 7.5 (3.88 mu Gy.m(2) to 0.5 mu Gy.m(2)) compared to slot-scanning x-ray (EOS). Due to this success, the flat detector and pulsed fluoroscopy technology can be an alternative to established methods such as X-ray and EOS in clinical use.Keywords
This publication has 17 references indexed in Scilit:
- Effects of Bracing in Adolescents with Idiopathic ScoliosisNew England Journal of Medicine, 2013
- Standardized way for imaging of the sagittal spinal balanceEuropean Spine Journal, 2011
- Radiation Dose Reduction in Scoliosis Patients: Low-Dose Full-Spine Radiography with Digital Flat Panel Detector and Image Stitching SystemRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2011
- Management of pediatric radiation dose using Philips fluoroscopy systems DoseWise: perfect image, perfect sensePediatric Radiology, 2006
- Prospective randomized comparison of radiation exposure from full spine radiographs obtained in three different techniquesEuropean Spine Journal, 2006
- Vergleich von konventioneller Wirbelsäulenganzaufnahme und fluoroskopischer Scan-Methode bei jungen Patienten mit idiopathischer SkolioseRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2005
- Digital Radiography of Scoliosis with a Scanning Method: Initial EvaluationRadiology, 2001
- Breast Cancer Mortality After Diagnostic RadiographySpine, 2000
- Elektronnaya vizualizatsiya ioniziruyushchego izlucheniya s pomoshch'yu ogranichennogo lavinnogo razryada v gazakhUspekhi Fizicheskih Nauk, 1993
- Breast Cancer in Women With Scoliosis Exposed to Multiple Diagnostic X RaysJNCI: Journal of the National Cancer Institute, 1989