Clinical Outcome of IM-Guided Total Knee Arthroplasty with Inappropriate Femoral Resection in Coronal Plane
Authors:
Open Access
- 30 March 2013
- journal article
- Published by Springer Nature in Knee Surgery & Related Research
- Vol. 25 (1) , 19-24
Abstract
The purpose of this study was to evaluate clinical results and accuracy of femoral cutting in the coronal plane in total knee arthroplasty (TKA) using a fixed length intramedullary guide. From 2005 to 2008, 101 patients (154 knees) underwent TKA (NexGen LPS implant). The minimal follow-up period was 3 years (mean, 4.4 years). The patients were divided into two groups (group 1, 94≤α angleα, 98≤α). Mechanical axis deviation (MAD), patellar tilting angle (PTA), Knee Society Knee Score (KSKS), and Knee Society Function Score (KSFS) were measured in both groups. There were 120 knees in group 1 and 34 knees in group 2. There was no significant intergroup difference in the postoperative MAD (group 1, 1.59°; group 2, 1.91°). The number of outliers with ≥2° MAD was 65 in group 1 and 24 in group 2. The mean PTA, KSKS, and KSFS were 10.17°, 96.0, and 96.6, respectively, in group 1 and 11.58°, 84.5, and 85.5, respectively, in group 2. The percentage of coronal alignment outliers was relatively high (34 in 154 cases, 22%) after TKA using a fixed length intramedullary guide. However, there was no statistically significant intergroup difference in clinical results (KSKS, p=0.67; KSFS, p=0.56).Keywords
This publication has 22 references indexed in Scilit:
- Good Alignment After Total Knee Arthroplasty Leads to Faster Rehabilitation and Better FunctionThe Journal of Arthroplasty, 2009
- Computer-assisted revision total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2004
- Computer-assisted knee arthroplasty versus a conventional jig-based techniqueThe Journal of Bone and Joint Surgery. British volume, 2004
- Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study.2003
- Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients.2002
- The accuracy of femoral intramedullary guides in total knee arthroplastyThe Journal of Arthroplasty, 1997
- Intramedullary Versus Extramedullary Femoral Alignment Systems in Total Knee ReplacementClinical Orthopaedics and Related Research, 1993
- Radiographic assessment of knee alignment after total knee arthroplastyThe Journal of Arthroplasty, 1988
- Total Joint Arthroplasty of the KneeClinical Orthopaedics and Related Research, 1985