Effect of platform switching on the peri-implant bone: A finite element study
Authors:
- K Bouazza-JuanesKBK Bouazza-Juanes
- Jj RodenasJRJj Rodenas
- Mv Lopez-MollaMLMv Lopez-Molla
Open Access
- 1 January 2015
- journal article
- Published by Medicina Oral, S.L. in Journal of Clinical and Experimental Dentistry
- Vol. 7 (4) , e483-e488
Abstract
There exists a relation between the presence and location of the micro-gap and the loss of peri implant bone. Several authors have shown that the treatments based on the use of platform switching result in less peri-implant bone loss and an increased tissue stability. The purpose of this study was to analyse the effect of the platform switching on the distribution of stresses on the peri-implant bone using the finite element method. A realistic 3D full-mandible finite element model representing cortical bone and trabecular bone was used to study the distribution of the stress on the bone induced by an implant of diameter 4.1 mm. Two abutments were modelled. The first one, of diameter 4.1 mm, was used in the reference model to represent a conventional implant. The second one, of diameter 3.2 mm, was used to represent the implant with platform switching. Both models were subjected to axial and oblique masticatory loads. The analyses showed that, although no relevant differences can be found for the trabecular bone, the use of platform switching reduces the maximum stress level in the cortical bone by almost 36% with axial loads and by 40% with oblique loads. The full 3D Finite Element model, that can be used to investigate the influence of other parameters (implant diameter, connexion type, …) on the biomechanical behaviour of the implant, showed that this stress reduction can be a biomechanical reasons to explain why the platform switching seems to reduce or eliminate crestal bone resorption after the prosthetic restoration. Dental implant, platform switching, finite element method.Keywords
This publication has 19 references indexed in Scilit:
- Effect of Platform Switching on Implant Crest Bone Stress: A Finite Element AnalysisImplant Dentistry, 2009
- Peri-Implant Bone Level Around Implants With Platform-Switched Abutments: Preliminary Data From a Prospective StudyJournal of Oral and Maxillofacial Surgery, 2007
- Factors Influencing the Preservation of the Periimplant Marginal BoneImplant Dentistry, 2007
- Benefits of an Implant Platform Modification Technique to Reduce Crestal Bone ResorptionImplant Dentistry, 2006
- Evaluation of Long‐Term Implant SuccessJournal of Periodontology, 2005
- AICRG, Part II: Crestal Bone Loss Associated with the Ankylos Implant: Loading to 36 MonthsJournal of Oral Implantology, 2004
- Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non‐Submerged and Submerged Implants in the Canine MandibleJournal of Periodontology, 2000
- The Effect of Inter‐Implant Distance on the Height of Inter‐Implant Bone CrestJournal of Periodontology, 2000
- Different types of inflammatory reactions in peri‐implant soft tissuesJournal of Clinical Periodontology, 1995
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981