One-Year Results of a Randomized Controlled Clinical Trial of Immediately Loaded Short Implants Placed in the Lower Posterior Single Molar Using a Complete Digital Workflow
Open Access
- 27 March 2019
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 9 (7) , 1282
Abstract
The purpose of this randomized clinical trial is to evaluate immediately loaded single implants with varying lengths in the posterior mandible using a fully digital, model-free prosthetic-driven implant planning pathway, and to compare clinical and radiological outcomes of short and long implants. The 52 patients with the single tooth missing in the posterior molar regions of the mandible were randomly assigned to the control (CMI IS-III active® long implant; 5.0 × 10 mm) and experimental (CMI IS-III active® short implant; 5.5 × 6.6, 7.3, 8.5 mm) groups. For each patient, a single implant was placed using the computer aided surgical template and all prostheses were fabricated by means of computer-aided design/computer-aided manufacturing (CAD/CAM) system on the virtual model. The patients received provisional and definitive monolithic zirconia prostheses at 1 week and 12 weeks after implant surgery, respectively. The implant stability quotient (ISQ) measurements and periapical radiographs were taken and peri-implant parameters were evaluated at 1, 3, 4, 8, 12, 24, 36, and 48 weeks after surgery. Nineteen long implants and 27 short implants were finally used for the statistical analysis. There was no significant difference between the groups in terms of insertion torque, ISQ values (except 3 weeks), marginal bone loss, and peri-implant soft tissue parameters (p > 0.05). Both groups exhibited no stability dip during the early phase of healing. The average marginal bone loss from the baseline of implant placement for the control and experimental groups was −0.07 and 0.03 mm after 12 weeks and 0.06 and 0.05 mm after 48 weeks. All of the soft tissue parameters were within normal limits. Within the limits of the short term follow up, immediate loading of short single implants can be considered as one of predictable treatment modality in mandible with reduced bone height when primary stability can be achieved.Keywords
Funding Information
- a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea . (HI16C1173)
This publication has 37 references indexed in Scilit:
- Computer‐guided implant therapy and soft‐ and hard‐tissue aspects. The Third EAO Consensus Conference 2012Clinical Oral Implants Research, 2012
- Long‐term outcomes of short dental implants supporting single crowns in posterior region: a clinical retrospective study of 5–10 yearsClinical Oral Implants Research, 2012
- A systematic review of the prognosis of short (<10 mm) dental implants placed in the partially edentulous patientJournal of Clinical Periodontology, 2011
- The role of primary stability for successful immediate loading of dental implants. A literature reviewJournal of Dentistry, 2010
- Bone Quality and the Immediate Loading of Implants—Critical Aspects Based on Literature, Research, and Clinical ExperienceImplant Dentistry, 2009
- Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installationClinical Oral Implants Research, 2007
- Biologic outcome of implant‐supported restorations in the treatment of partial edentulismClinical Oral Implants Research, 2002
- Implant Survival to 36 Months as Related to Length and DiameterAnnals of Periodontology, 2000
- A 5‐year prospective clinical and radiographic study of non‐submerged dental implantsClinical Oral Implants Research, 2000
- Long‐term evaluation of non‐submerged ITI implants. Part 1: 8‐year life table analysis of a prospective multi‐center study with 2359 implants.Clinical Oral Implants Research, 1997