Unbiased centroiding of point targets close to the Cramer Rao limit
- 9 January 2024
- journal article
- research article
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 41 (2) , 195-206
Abstract
Systematic errors affecting center -of -gravity (CoG) measurements may occur from coarse sampling of the pointspread -function (PSF) or from signal truncation at the boundaries of the region -of -interest (ROI). For small ROI and PSF widths, these effects are shown to become dominant, but this can be mitigated by introducing novel unbiased estimators that are largely free of systematic error and perform particularly well for low photon numbers. Analytical expressions for the estimator variances, comprising contributions from photon shot noise, random pixel noise, and residual systematic error, are derived and verified by Monte Carlo simulations. The accuracy and computational speed of the unbiased estimators are compared to those of other common estimators, including iteratively weighted CoG, thresholded CoG, iterative least squares fitting, and two-dimensional Gaussian regression. Each estimator is optimized with respect to ROI size and PSF radius and its error compared to the theoretical limit defined by the Cramer Rao lower bound (CRLB). The unbiased estimator with full systematic error correction operating on a small ROI [3 x 3] emerges as one of the most accurate estimators while requiring significantly less computing effort than alternative algorithms. (c) 2024 Optica Publishing GroupKeywords
All Related Versions
This publication has 27 references indexed in Scilit:
- Microscopy and its focal switchNature Methods, 2008
- Precise Nanometer Localization Analysis for Individual Fluorescent ProbesBiophysical Journal, 2002
- Accuracy performance of star trackers - a tutorialIEEE Transactions on Aerospace and Electronic Systems, 2002
- Analysis of optimal centroid estimation applied to Shack–Hartmann sensingApplied Optics, 1999
- Wave-front sensors1999
- Convergence Properties of the Nelder--Mead Simplex Method in Low DimensionsSIAM Journal on Optimization, 1998
- Accuracy analysis of a Hartmann-Shack wavefront sensor operated with a faint objectOptical Engineering, 1994
- Elimination of systematic error in subpixel accuracy centroid estimation [also Letter 34(11)3347-3348(Nov1995)]Optical Engineering, 1991
- Cramér–Rao lower bounds on the performance of charge-coupled-device optical position estimatorsJournal of the Optical Society of America A, 1986
- Performance Analysis And Size Optimization Of Focal Planes For Point-Source Tracking Algorithm ApplicationsOptical Engineering, 1984