A Quadrupole Ion Trap and Fourier Transform Ion Cyclotron Resonance Concerted Study of the Kinetics of an Ion/Molecule Association Reaction: A Chemometric Approach
Authors:
- Pierre-Charles MariaPMPierre-Charles Maria
- Lorenza OpertiLOLorenza Operti
- Roberto RabezzanaRoberto Rabezzana
- Gian Angelo VaglioGVGian Angelo Vaglio
- 1 October 2003
- journal article
- research article
- Published by SAGE Publications in European Journal of Mass Spectrometry
- Vol. 9 (5) , 435-444
Abstract
The effects of different experimental parameters on rate constant measurements performed by mass spectrometry were investigated with a two-level fractional factorial design. This chemometric technique allows a study of the effects of selected factors and of their interactions on the response of an experiment by performing a limited number of analyses. The selected factors were: sample pressure, energy of the ionising electrons, reaction time and ionisation time. In this work, two mass spectrometric techniques were compared: Fourier transform ion cyclotron resonance (FT-ICR) and quadrupole ion trap (QIT) mass spectrometries. Experimental results were obtained from a study of a reaction system consisting of the condensation between triethylphosphite and its fragment ion (CH3CH2O)2P+. Apparent bimolecular rate constants are clearly larger when determined by QIT than by FT-ICR, because of collisional stabilisation of the adduct ion by helium buffer gas introduced in the QIT spectrometer. However, the QIT rate constant extrapolated to zero helium pressure is almost identical to the FT-ICR value; this supports the conclusion regarding the buffer gas effect. Minor effects evidenced by the chemometric method were attributed to the sample pressure and to the reaction time.Keywords
This publication has 14 references indexed in Scilit:
- Gas-phase ion-molecule reactions in organophosphorus estersJournal of Mass Spectrometry, 1999
- Experimental and Theoretical Study of the Formation of Silicon−Carbon Ion Species in Gaseous Silane/Ethene MixturesThe Journal of Physical Chemistry A, 1999
- Chemometric approach to evaluate the parameters affecting the determination of reaction rate constants by ion trap mass spectrometryJournal of the American Society for Mass Spectrometry, 1998
- Experimental design and optimizationChemometrics and Intelligent Laboratory Systems, 1998
- Influence of ion activation and thermalization effects on reaction rate constants in a quadrupole ion trap mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1997
- Reliability of Fourier transform-ion cyclotron resonance determinations of rate constants for ion/molecule reactionsEuropean Journal of Mass Spectrometry, 1996
- Radiative Association of NO+ with 3-Pentanone: Rate, Binding Energy, and Temperature DependenceJournal of the American Chemical Society, 1996
- Probing trapped ion energies via ion-molecule reaction kinetics: Fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 1992
- Third-body effects in termolecular reactions. Halide ion addition to boron trifluoride and boron trichlorideThe Journal of Physical Chemistry, 1984
- Empirical methods for determination of ionization gauge relative sensitivities for different gasesVacuum, 1983